Optimal Tuned Mass Dampers for Buildings
The DOI matches its Crossref record.
Abstract
This note has presented approximate formulas for the design of a TMD system. For most buildings, the accuracy obtained from the closed form expressions is adequate for preliminary design. This note has also shown, using results of the feasibility study of the Citicorp Center TMD, that the effective damping of a building with a TMD is smaller than predicted by a model that represents the building by its first mode only.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Optimal design theories and applications of tuned mass dampers
Lee, C.-L., Chen, Y.-T., Chung, L.-L., & Wang, Y.-P. (2006) · Engineering Structures · doi:10.1016/j.engstruct.2005.06.023 · Cited by 296
Murtagh, P. J., Ghosh, A., Basu, B., & Broderick, B. M. (2008) · Wind Energy · doi:10.1002/we.249 · Cited by 278
Optimal Placement of Multiple Tune Mass Dampers for Seismic Structures
Chen, G., & Wu, J. (2001) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2001)127:9(1054 · Cited by 188
Ueng, J., Lin, C., & Wang, J. (2008) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.336 · Cited by 36
Bioinspired Tuned Mass Damper for Mitigation of Wind-Induced Building Excitation
Kwon, I. Y., Yang, H. T., Hansma, P. K., & Randall, C. J. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001881 · Cited by 12
Seismic Energy Dissipation of Inelastic Structures with Tuned Mass Dampers
(2008) · doi:10.1061/(asce)0733-9399(2008)134:2(163
Metadata
- Authors
- Luft, R. W.
- Venue
- Journal of the Structural Division
- Published
- 1979-12
- Volume
- 105
- Issue
- 12
- Pages
- 2766-2772
- ISSN
- 0044-8001 (ISSN-L)
- 2690-3377
- OpenAlex
- W1949648717
- Cited by
- 146
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.