Optimal Placement of Multiple Tune Mass Dampers for Seismic Structures
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Effects of a tuned mass damper on the modal responses of a six-story building structure are studied first to demonstrate the damper's ineffectiveness in seismic applications. Multistage and multimode tuned mass dampers are then introduced. Several optimal location indices are defined based on intuitive reasoning, and a sequential procedure is proposed for practical design and placement of the dampers in seismically excited building structures. The proposed procedure is applied to place the dampers on the floors of the six-story building for maximum reduction of the accelerations under a stochastic seismic load and 13 earthquake records. Numerical results show that the multiple dampers can effectively reduce the acceleration of the uncontrolled structure by 10–25% more than a single damper. Time-history analyses indicate that the multiple dampers weighing 3% of total structural weight can reduce the floor acceleration up to 40%. The multiple dampers can even suppress the peak of acceleration responses due to impulsive excitations, which a single damper of equal mass cannot achieve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,043
Dynamic characterization of multiple tuned mass dampers and some design formulas
Abé, M., & Fujino, Y. (1994) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290230802 · Cited by 329
Dynamic characteristics of multiple substructures with closely spaced frequencies
Xu, K., & Igusa, T. (1992) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290211203 · Cited by 326
Tuned Mass Dampers for Buildings
McNamara, R. J. (1977) · Journal of the Structural Division · doi:10.1061/jsdeag.0004721 · Cited by 319
Performance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306
Vibration Control Using Multiple Tuned Mass Dampers
Igusa, T., & Xu, K. (1994) · Journal of Sound and Vibration · doi:10.1006/jsvi.1994.1341 · Cited by 295
Optimal Tuned Mass Dampers for Buildings
Luft, R. W. (1979) · Journal of the Structural Division · doi:10.1061/jsdeag.0005323 · Cited by 146
Tuned mass dampers for structures with closely spaced natural frequencies
Abé, M., & Igusa, T. (1995) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290240209 · Cited by 122
Minimal structural response under random excitation using the vibration absorber
Wirsching, P. H., & Campbell, G. W. (1973) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290020402 · Cited by 120
The Past and Future of Seismic Effectiveness of Tuned Mass Dampers
Chowdhury, A. H., Iwuchukwu, M. D., & Garske, J. J. (1987) · Springer eBooks · doi:10.1007/978-94-009-3525-9_7 · Cited by 37
Research works printed but not linked: 4
- Chang M. I. J. and Soong T. T. ( 1980). “Optimal controller placement in modal control of complex systems.” J. Math. Ana. Appl. 75(2) 340–358. · doi:10.1016/0022-247x(80)90084-0
- Chen G. ( 1996). “Multi-stage tuned mass dampers.” Proc. 11th World Conf. Earthquake Engrg. Elsevier Science Amsterdam.
- Clark A. J. ( 1988). “Multiple passive tuned mass dampers for reducing earthquake induced building motion.” Proc. 9th World Conf. Earthquake Engrg. Vol. V 779–784.
- Zhang R. ( 1990). “Structural response control by additive viscoelastic dampers.” PhD dissertation State University of New York at Buffalo Buffalo.
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Optimal tuned mass damper for seismic applications and practical design formulas
Hoang, N., Fujino, Y., & Warnitchai, P. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2007.05.007 · Cited by 382
Dai, J., Xu, Z.-D., & Gai, P.-P. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2019.109585 · Cited by 163
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
“Therefore, STMDs are prone to some problems such as mistuning, off-optimum damping, and weak performance for reduction of response when structures had multimode [50].”
BackgroundRobust design optimization of TMDs in vehicle–bridge coupled vibration problems
Miguel, L. F. F., Lopez, R. H., Torii, A. J., Miguel, L. F. F., & Beck, A. T. (2016) · Engineering Structures · doi:10.1016/j.engstruct.2016.08.033 · Cited by 104
Metadata
- Authors
- Chen, G., & Wu, J.
- Venue
- Journal of Structural Engineering
- Published
- 2001-09
- Volume
- 127
- Issue
- 9
- Pages
- 1054-1062
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2001)127:9(1054
- OpenAlex
- W2024778470
- Cited by
- 188
- References
- 10
- FWCI
- 13.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Placement of Multiple Tune Mass Dampers for Seismic Structures. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(2001)127:9(1054
- The paper
- Chen, G., & Wu, J. (2001). Optimal Placement of Multiple Tune Mass Dampers for Seismic Structures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(2001)127%3A9(1054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.