The DOI matches its Crossref record.
Improved fiber-optic interferometer for atomic force microscopy
Abstract
A high-sensitivity fiber-optic displacement sensor for atomic force microscopy is described. The sensor is based on the optical interference occurring in the micron-sized cavity formed between the cleaved end of a single-mode optical fiber and the microscope cantilever. As a result of using a diode laser light source and all-fiber construction, the sensor is compact, mechanically robust, and exhibits good low-frequency noise behavior. Peak-to-peak noise in a dc to 1 kHz bandwidth is less than 0.1 Å. Images are presented demonstrating atomic resolution of graphite and magnetic force imaging of bits written on a magnetic disk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feedback Cooling of a Cantilever’s Fundamental Mode below 5 mK
Poggio, M., Degen, C. L., Mamin, H. J., & Rugar, D. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.017201 · Cited by 371
Self-citationJ. Phys.: Condens. Matter, 13, 619
(2001) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/13/31/202 · Cited by 206
First images from a magnetic resonance force microscope
Züger, O., & Rugar, D. (1993) · Applied Physics Letters · doi:10.1063/1.110460 · Cited by 97
Self-citation
Metadata
- Authors
- Rugar, D., Mamin, H. J., & Guethner, P.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1989-12-18
- Volume
- 55
- Issue
- 25
- Pages
- 2588-2590
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2011109350
- Cited by
- 629
- References
- 0
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved fiber-optic interferometer for atomic force microscopy. https://app.cochat.ai/papers/10.1063/1.101987
- The paper
- Rugar, D., Mamin, H. J., & Guethner, P. (1989). Improved fiber-optic interferometer for atomic force microscopy. Applied Physics Letters. https://doi.org/10.1063/1.101987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.