The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Kelvin probe force microscopy
Abstract
Measurements of the contact potential difference between different materials have been performed for the first time using scanning force microscopy. The instrument has a high resolution for both the contact potential difference (better than 0.1 mV) and the lateral dimension (<50 nm) and allows the simultaneous imaging of topography and contact potential difference. Images of gold, platinum, and palladium surfaces, taken in air, show a large contrast in the contact potential difference and demonstrate the basic concept.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Institute of Physics Handbook
Dayton, I. E. (1964) · American Journal of Physics · doi:10.1119/1.1970399 · Cited by 3,000
Review of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Self-citationLow-Energy Electrons and Surface Chemistry
Ertl, G., Küppers, J., & Park, R. L. (1976) · Physics Today · doi:10.1063/1.3023372 · Cited by 770
Observation of single charge carriers by force microscopy
Schönenberger, C., & Alvarado, S. F. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.3162 · Cited by 267
Sachtler, W. M. H., Dorgelo, G. J. H., & Holscher, A. A. (1966) · Surface Science · doi:10.1016/0039-6028(66)90083-5 · Cited by 252
Cited by
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Kelvin probe force microscopy and its application
Melitz, W., Shen, J., Kummel, A. C., & Lee, S. (2011) · Surface Science Reports · doi:10.1016/j.surfrep.2010.10.001 · Cited by 1,718
Surface photovoltage phenomena: theory, experiment, and applications
Kronik, L. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00002-3 · Cited by 1,648
Chiral molecules and the electron spin
Naaman, R., Paltiel, Y., & Waldeck, D. H. (2019) · Nature Reviews Chemistry · doi:10.1038/s41570-019-0087-1 · Cited by 934
Large-Area Epitaxial Monolayer MoS2
Dumcenco, D., Ovchinnikov, D., Marinov, K., Lazić, P., Gibertini, M., Marzari, N., Sanchez, O. L., Kung, Y.-C., Krasnozhon, D., Chen, M.-W., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b01281 · Cited by 888
Metadata
- Authors
- Nonnenmacher, M., O’Boyle, M. P., & Wickramasinghe, H. K.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1991-06-24
- Volume
- 58
- Issue
- 25
- Pages
- 2921-2923
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1970138328
- Cited by
- 2,343
- References
- 6
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.