The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Near-field magneto-optics and high density data storage
Abstract
Near-field scanning optical microscopy (NSOM) has been used to image and record domains in thin-film magneto-optic (MO) materials. In the imaging mode, resolution of 30–50 nm has been consistently obtained, whereas in the recording mode, domains down to ∼60 nm have been written reproducibly. Data densities of ∼45 Gbits/in.2 have been achieved, well in excess of current magnetic or MO technologies. A brief analysis of speed and other issues indicates that the technique may represent a viable alternative to these and other methods for anticipated high density data storage needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Three-dimensional optical data storage in refractive media by two-photon point excitation
Strickler, J. H., & Webb, W. W. (1991) · Optics Letters · doi:10.1364/ol.16.001780 · Cited by 627
Cited by
Optical storage arrays: a perspective for future big data storage
Gu, M., Li, X., & Cao, Y. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.58 · Cited by 542
Metadata
- Authors
- Betzig, E., Trautman, J. K., Wolfe, R., Gyorgy, E. M., Finn, P. L., Kryder, M. H., & Chang, C.-H.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1992-07-13
- Volume
- 61
- Issue
- 2
- Pages
- 142-144
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2016763315
- Cited by
- 753
- References
- 2
- FWCI
- 19.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-field magneto-optics and high density data storage. https://app.cochat.ai/papers/10.1063/1.108198
- The paper
- Betzig, E., Trautman, J. K., Wolfe, R., Gyorgy, E. M., Finn, P. L., Kryder, M. H., & Chang, C.-H. (1992). Near-field magneto-optics and high density data storage. Applied Physics Letters. https://doi.org/10.1063/1.108198
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.