The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Near-field magneto-optics and high density data storage
Abstract
Near-field scanning optical microscopy (NSOM) has been used to image and record domains in thin-film magneto-optic (MO) materials. In the imaging mode, resolution of 30–50 nm has been consistently obtained, whereas in the recording mode, domains down to ∼60 nm have been written reproducibly. Data densities of ∼45 Gbits/in.2 have been achieved, well in excess of current magnetic or MO technologies. A brief analysis of speed and other issues indicates that the technique may represent a viable alternative to these and other methods for anticipated high density data storage needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Self-citationThree-dimensional optical data storage in refractive media by two-photon point excitation
Strickler, J. H., & Webb, W. W. (1991) · Optics Letters · doi:10.1364/ol.16.001780 · Cited by 627
Williams, C. C., & Wickramasinghe, H. K. (1986) · Applied Physics Letters · doi:10.1063/1.97288 · Cited by 413
Charge storage in a nitride-oxide-silicon medium by scanning capacitance microscopy
Barrett, R. C., & Quate, C. F. (1991) · Journal of Applied Physics · doi:10.1063/1.349388 · Cited by 245
Cited by
Diarylethenes for Memories and Switches
Irie, M. (2000) · Chemical Reviews · doi:10.1021/cr980069d · Cited by 4,157
Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
Betzig, E., & Trautman, J. K. (1992) · Science · doi:10.1126/science.257.5067.189 · Cited by 1,808
Self-citationThree-Dimensional Optical Data Storage Using Photochromic Materials
Kawata, S., & Kawata, Y. (2000) · Chemical Reviews · doi:10.1021/cr980073p · Cited by 1,479
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Self-citationHeat Assisted Magnetic Recording
Kryder, M. H., Gage, E. C., McDaniel, T. W., Challener, W. A., Rottmayer, R. E., Ju, G., Hsia, Y.-T., & Erden, M. F. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.2004315 · Cited by 1,079
Self-citation
Metadata
- Authors
- Betzig, E., Trautman, J. K., Wolfe, R., Gyorgy, E. M., Finn, P. L., Kryder, M. H., & Chang, C.-H.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1992-07-13
- Volume
- 61
- Issue
- 2
- Pages
- 142-144
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2016763315
- Cited by
- 753
- References
- 5
- FWCI
- 19.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.