The DOI matches its Crossref record.
Simultaneous measurement of the thermal conductivity and the thermal diffusivity of liquids by the transient hot-wire method
Abstract
The paper describes a method and an instrument to measure the thermal conductivity and the thermal diffusivity of liquids simultaneously by the transient hot-wire method. Though the principle of this method has formerly been known, the practical application to fluids has been enabled only by high-precision measurement. In the present method, the thermal conductivity can be determined from the slope of the temperature rise against time of electrically-heated wire and the thermal diffusivity can be obtained from the slope and the absolute temperature rise. In this instrument, the absolute temperature rise, which is detected as voltage change of an unbalanced bridge, is recorded by a high-precision digital system. This method has been tested by measuring toluene in the temperature range 0 °–80 °C at atmospheric pressure. The accuracy of the thermal conductivity measurement is estimated as ±0.5%, whereas that of the thermal diffusivity measurement is ±5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermochemistry of ionic liquid heat-transfer fluids
Valkenburg, M. E. V., Vaughn, R. L., Williams, M., & Wilkes, J. S. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2004.11.013 · Cited by 595
Nagasaka, Y., & Nagashima, A. (1981) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/14/12/020 · Cited by 365
Self-citationThermal Characterization and Analysis of Microliter Liquid Volumes Using the Three-Omega Method
Roy-Panzer, S., Kodama, T., Lingamneni, S., Panzer, M. A., Asheghi, M., & Goodson, K. E. (2015) · Review of Scientific Instruments · doi:10.1063/1.4907353 · Cited by 20
Metadata
- Authors
- Nagasaka, Y., & Nagashima, A.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1981-02-01
- Volume
- 52
- Issue
- 2
- Pages
- 229-232
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2049308136
- Cited by
- 173
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.