The DOI matches its Crossref record.
An application of electrothermal feedback for high resolution cryogenic particle detection
Abstract
A novel type of superconducting transition edge sensor is proposed. In this sensor, the temperature of a superconducting film is held constant by feeding back to its position on the resistive transition edge. Energy deposited in the film is measured by a reduction in the feedback Joule heating. This mode of operation should lead to substantial improvements in resolution, linearity, dynamic range, and count rate. Fundamental resolution limits are below ΔE=√kT2C, which is sometimes incorrectly referred to as the thermodynamic limit. This performance is better than any existing technology operating at the same temperature, count rate, and absorber heat capacity. Applications include high resolution x-ray spectrometry, dark matter searches, and neutrino detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ladd, T. D., Jelezko, F., Laflamme, R., Nakamura, Y., Monroe, C., & O’Brien, J. L. (2010) · Nature · doi:10.1038/nature08812 · Cited by 3,592
Detection ofB-Mode Polarization at Degree Angular Scales by BICEP2
Ade, P. A. R., Aikin, R. W., Barkats, D., Benton, S. J., Bischoff, C. A., Bock, J. J., Brevik, J. A., Buder, I., Bullock, E., Dowell, C. D., et al. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.241101 · Cited by 1,571
Self-citationOpportunities for mesoscopics in thermometry and refrigeration: Physics and applications
Giazotto, F., Heikkilä, T. T., Luukanen, A., Savin, A. M., & Pekola, J. P. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.217 · Cited by 1,058
Superconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Counting near-infrared single-photons with 95% efficiency
Lita, A. E., Miller, A. J., & Nam, S. W. (2008) · Optics Express · doi:10.1364/oe.16.003032 · Cited by 734
Superconducting Microresonators: Physics and Applications
Zmuidzinas, J. (2012) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-020911-125022 · Cited by 645
Experimental Long-Distance Decoy-State Quantum Key Distribution Based on Polarization Encoding
Peng, C.-Z., Zhang, J., Yang, D., Gao, W.-B., Ma, H.-X., Yin, H., Zeng, H.-P., Yang, T., Wang, X.-B., & Pan, J.-W. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.010505 · Cited by 384
Cabrera, B., Clarke, R. M., Colling, P., Miller, A. J., Nam, S., & Romani, R. W. (1998) · Applied Physics Letters · doi:10.1063/1.121984 · Cited by 352
Long-Distance Decoy-State Quantum Key Distribution in Optical Fiber
Rosenberg, D., Harrington, J. W., Rice, P. R., Hiskett, P. A., Peterson, C. G., Hughes, R. J., Lita, A. E., Nam, S. W., & Nordholt, J. E. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.010503 · Cited by 348
Terahertz detectors and focal plane arrays
Rogalski, A., & Sizov, F. (2011) · Opto-Electronics Review · doi:10.2478/s11772-011-0033-3 · Cited by 345
Superconducting detectors and mixers for millimeter and submillimeter astrophysics
Zmuidzinas, J., & Richards, P. L. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2004.833670 · Cited by 294
Demonstration of a low-noise near-infrared photon counter with multiphoton discrimination
Miller, A. J., Nam, S. W., Martinis, J. M., & Sergienko, A. V. (2003) · Applied Physics Letters · doi:10.1063/1.1596723 · Cited by 285
Neutrino physics from the cosmic microwave background and large scale structure
Abazajian, K. N., Arnold, K., Austermann, J., Benson, B. A., Bischoff, C., Bock, J., Bond, J. R., Borrill, J., Calabrese, E., Carlstrom, J. E., et al. (2015) · Astroparticle Physics · doi:10.1016/j.astropartphys.2014.05.014 · Cited by 280
Self-citationProgress in focal plane array technologies
Rogalski, A. (2012) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2012.07.001 · Cited by 276
Fukuda, D., Fujii, G., Numata, T., Amemiya, K., Yoshizawa, A., Tsuchida, H., Fujino, H., Ishii, H., Itatani, T., Inoue, S., et al. (2011) · Optics Express · doi:10.1364/oe.19.000870 · Cited by 271
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
Toward the discovery of matter creation with neutrinoless ββ decay
Agostini, M., Benato, G., Detwiler, J. A., Menéndez, J., & Vissani, F. (2023) · Reviews of Modern Physics · doi:10.1103/revmodphys.95.025002 · Cited by 260
Noise-free high-efficiency photon-number-resolving detectors
Rosenberg, D., Lita, A., Miller, A., & Nam, S. (2005) · Physical Review A · doi:10.1103/physreva.71.061803 · Cited by 242
Gerrits, T., Thomas-Peter, N., Gates, J. C., Lita, A. E., Metcalf, B. J., Calkins, B., Tomlin, N. A., Fox, A. E., Linares, A. L., Spring, J. B., et al. (2011) · Physical Review A · doi:10.1103/physreva.84.060301 · Cited by 88
Garwe, F., Schmidt, A., Zieger, G., May, T., Wynne, K., Hübner, U., Zeisberger, M., Paa, W., Stafast, H., & Meyer, H.-G. (2011) · Applied Physics B · doi:10.1007/s00340-011-4377-7 · Cited by 20
Metadata
- Authors
- Irwin, K. D.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1995-04-10
- Volume
- 66
- Issue
- 15
- Pages
- 1998-2000
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1979659160
- Cited by
- 685
- References
- 0
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.