The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Retarding-field analyzer for measurements of ion energy distributions and secondary electron emission coefficients in low-pressure radio frequency discharges
Abstract
A four-grid electrostatic energy analyzer for measurements of the ion velocity distribution and the emission of secondary electrons on the electrodes of low-pressure radio frequency glow-discharge systems has been conceived. Problems arising from poor analyzer design are discussed and the performance of the presented analyzer is shown for measurements of the ion velocity distribution in pure hydrogen, helium, and argon discharges. Moreover, the secondary electron yields on aluminium, stainless steel, copper, and amorphous silicon exposed to radio frequency argon, helium, and hydrogen plasmas are determined in situ, for the first time to our knowledge. In parallel-plate radio frequency discharges secondary electron emission involves the contributions of ions, fast neutrals, metastables, and photons impinging on the electrode surfaces. Therefore, secondary electron emission must be considered as a global phenomenon. Global secondary electron emission can be up to ten times larger than only ion-induced secondary electron emission. Typically, the global emission coefficient is of the order of 0.1 (secondary electrons per ion) but can exceed 1 when the contribution of metastables is important. This is a noteworthy result since secondary electron emission is often neglected or underestimated in modeling of electrical discharges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Imprisonment of Resonance Radiation in Gases
Holstein, T. (1947) · Physical Review · doi:10.1103/physrev.72.1212 · Cited by 1,470
Lerner, R. G., & Trigg, G. L. (1991) · Cited by 1,153
Brown, S. C., & Singer, S. F. (1961) · Physics Today · doi:10.1063/1.3057402 · Cited by 1,112
Elementary Processes in Hydrogen-Helium Plasmas
Janev, R. K., Langer, W. D., Post, D. E., & Evans, K. (1987) · Springer eBooks · doi:10.1007/978-3-642-71935-6 · Cited by 749
Godyak, V. A., & Piejak, R. B. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.996 · Cited by 563
Transition between different regimes of rf glow discharges
Belenguer, P., & Boeuf, J. P. (1990) · Physical Review A · doi:10.1103/physreva.41.4447 · Cited by 363
Particle simulations of radio-frequency glow discharges
Surendra, M., & Graves, D. B. (1991) · IEEE Transactions on Plasma Science · doi:10.1109/27.106808 · Cited by 254
Monte-Carlo simulation of electron properties in rf parallel plate capacitively coupled discharges
Kushner, M. J. (1983) · Journal of Applied Physics · doi:10.1063/1.332763 · Cited by 181
Effect of Monolayer Adsorption on the Ejection of Electrons from Metals by Ions
Hagstrum, H. D. (1956) · Physical Review · doi:10.1103/physrev.104.1516 · Cited by 123
Cited by
Phelps, A. V., & Petrovic, Z. L. (1999) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/8/3/201 · Cited by 905
Metadata
- Authors
- Böhm, C., & Perrin, J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1993-01-01
- Volume
- 64
- Issue
- 1
- Pages
- 31-44
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2108149579
- Cited by
- 252
- References
- 10
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.