The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Practical nitric oxide measurement employing a nitric oxide-selective electrode
Abstract
An NO-selective electrode was developed as an easily applicable tool for a real-time nitric oxide (NO) measurement. The working electrode (0.2 mm diam) was made from Pt/Ir alloy coated with a three-layered membrane. The counterelectrode was made from a carbon fiber. When a stable NO donor, S-nitroso-N-acetyl-dl-penicillamine, was applied, the electrode current increased in a dose-dependent fashion. The current and calculated NO concentration showed a linear relationship in the range from 0.2 nM (S/N=1) to 1 μM of NO. The response of the electrode was 1.14±0.09 s. The effects of temperature, pH, and chemicals other than NO on the electrode current were also evaluated. Electrodes which were placed in the luminal side of rat aortic rings exhibited 30 pA of current due to NO generation induced by the addition of 10−6 M of acetylcholine. The current was eliminated in the presence of 50 μM NG-monomethyl-L-arginine, an inhibitor of NO synthase. Thus, this NO-selective electrode is applicable to real-time NO assay in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
Palmer, R. M. J., Ferrige, A. G., & Moncada, S. (1987) · Nature · doi:10.1038/327524a0 · Cited by 10,704
Ignarro, L. J., Lippton, H., Edwards, J. C., Baricos, W. H., Hyman, A. L., Kadowitz, P. J., & Gruetter, C. A. (1981) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)32738-2 · Cited by 1,633
Cited by
Polymers in sensor applications
Adhikari, B., & Majumdar, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.03.002 · Cited by 1,181
Monitoring Rapid Chemical Communication in the Brain
Robinson, D. L., Hermans, A., Seipel, A. T., & Wightman, R. M. (2008) · Chemical Reviews · doi:10.1021/cr068081q · Cited by 669
Nitric oxide released from activated platelets inhibits platelet recruitment.
Freedman, J. E., Loscalzo, J., Barnard, M. R., Alpert, C., Keaney, J. F., & Michelson, A. D. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119540 · Cited by 389
Noiri, E., Peresleni, T., Miller, F., & Goligorsky, M. S. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118681 · Cited by 343
Pollman, M. J., Yamada, T., Horiuchi, M., & Gibbons, G. H. (1996) · Circulation Research · doi:10.1161/01.res.79.4.748 · Cited by 341
Metadata
- Authors
- Ichimori, K., Ishida, H., Fukahori, M., Nakazawa, H., & Murakami, E.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1994-08-01
- Volume
- 65
- Issue
- 8
- Pages
- 2714-2718
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2000641107
- Cited by
- 180
- References
- 2
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical nitric oxide measurement employing a nitric oxide-selective electrode. https://app.cochat.ai/papers/10.1063/1.1144674
- The paper
- Ichimori, K., Ishida, H., Fukahori, M., Nakazawa, H., & Murakami, E. (1994). Practical nitric oxide measurement employing a nitric oxide-selective electrode. Review of Scientific Instruments. https://doi.org/10.1063/1.1144674
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.