The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thin film microcalorimeter for heat capacity measurements from 1.5 to 800 K
Abstract
A new microcalorimeter for measuring heat capacity of thin films in the range 1.5–800 K is described. Semiconductor processing techniques are used to create a device with an amorphous silicon nitride membrane as the sample substrate, a Pt thin film resistor for temperatures greater than 40 K, and either a thin film amorphous Nb–Si or a novel boron-doped polycrystalline silicon thermometer for lower temperatures. The addenda of the device, including substrate, is 4×10−6 J/K at room temperature and 2×10−9 J/K at 4.3 K, approximately two orders of magnitude less than any existing calorimeter used for measuring thin films. The device is capable of measuring the heat capacity of thin film samples as small as a few micrograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Conductivity and Specific Heat of Noncrystalline Solids
Zeller, R. C., & Pohl, R. O. (1971) · Physical Review B · doi:10.1103/physrevb.4.2029 · Cited by 1,954
Cited by
Si-N membrane-based microcalorimetry: Heat capacity and thermal conductivity of thin films
Revaz, B., Zink, B. L., & Hellman, F. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2005.04.004 · Cited by 43
Self-citation
Metadata
- Authors
- Denlinger, D. W., Abarra, E. N., Allen, K., Rooney, P. W., Messer, M. T., Watson, S. K., & Hellman, F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1994-04-01
- Volume
- 65
- Issue
- 4
- Pages
- 946-959
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1989573808
- Cited by
- 248
- References
- 1
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thin film microcalorimeter for heat capacity measurements from 1.5 to 800 K. https://app.cochat.ai/papers/10.1063/1.1144925
- The paper
- Denlinger, D. W., Abarra, E. N., Allen, K., Rooney, P. W., Messer, M. T., Watson, S. K., & Hellman, F. (1994). Thin film microcalorimeter for heat capacity measurements from 1.5 to 800 K. Review of Scientific Instruments. https://doi.org/10.1063/1.1144925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.