The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
High resolution x-ray absorption spectroscopy with absolute energy calibration for the determination of absorption edge energies
Abstract
The general characteristics and spectrometric features of a high resolution four-crystal reflection x-ray monochromator with wavelength analysis installed at the HASYLAB beam line L at DESY are presented. The monochromator is part of a spectrometer developed to calibrate x-ray absorption edge spectra in the energy range of 6–36 keV with a relative uncertainty ΔE/E from 10−5 to 10−6. This requires an extremely effective suppression of harmonics and also a negligible instrumental influence in order to obtain almost intrinsic spectra. As the results show, the monochromator fulfills the requirements, including very high stability. An example of the calibration procedure for the copper K edge is given as well as a comparison of the remeasured absorption edge energies with the previously tabulated data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warren, Β. E. (1968) · Cited by 5,832
BEARDEN, J. A. (1967) · Reviews of Modern Physics · doi:10.1103/revmodphys.39.78 · Cited by 1,809
Dynamical Diffraction of X Rays by Perfect Crystals
BATTERMAN, B. W., & COLE, H. (1964) · Reviews of Modern Physics · doi:10.1103/revmodphys.36.681 · Cited by 1,438
Precision lattice constant determination
Bond, W. L. (1960) · Acta Crystallographica · doi:10.1107/s0365110x60001941 · Cited by 701
Absolute energy calibration of X-ray radiation from synchrotron sources
Pettifer, R. F., & Hermes, C. (1985) · Journal of Applied Crystallography · doi:10.1107/s0021889885010627 · Cited by 127
Cited by
Qiu, B., Zhang, M., Wu, L., Wang, J., Xia, Y., Qian, D., Liu, H., Hy, S., Chen, Y., An, K., et al. (2016) · Nature Communications · doi:10.1038/ncomms12108 · Cited by 734
Bioinspired Metal–Organic Framework Catalysts for Selective Methane Oxidation to Methanol
Baek, J., Rungtaweevoranit, B., Pei, X., Park, M., Fakra, S. C., Liu, Y.-S., Matheu, R., Alshmimri, S. A., Alshehri, S., Trickett, C. A., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11525 · Cited by 417
Determination of Mn valence states in mixed-valent manganates by XANES spectroscopy
Manceau, A., Marcus, M. A., & Grangeon, S. (2012) · American Mineralogist · doi:10.2138/am.2012.3903 · Cited by 351
Nano-structured rhodium doped SrTiO3–Visible light activated photocatalyst for water decontamination
Kiss, B., Manning, T. D., Hesp, D., Didier, C., Taylor, A., Pickup, D. M., Chadwick, A. V., Allison, H. E., Dhanak, V. R., Claridge, J. B., et al. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.01.066 · Cited by 89
Can Mn–S redox cycling drive sedimentary dolomite formation? A hypothesis
Petrash, D. A., Lalonde, S. V., González-Arismendi, G., Gordon, R. A., Méndez, J. A., Gingras, M. K., & Konhauser, K. O. (2015) · Chemical Geology · doi:10.1016/j.chemgeo.2015.03.017 · Cited by 46
Metadata
- Authors
- Kraft, S., Stümpel, J., Becker, P., & Kuetgens, U.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1996-03-01
- Volume
- 67
- Issue
- 3
- Pages
- 681-687
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2049302850
- Cited by
- 273
- References
- 5
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High resolution x-ray absorption spectroscopy with absolute energy calibration for the determination of absorption edge energies. https://app.cochat.ai/papers/10.1063/1.1146657
- The paper
- Kraft, S., Stümpel, J., Becker, P., & Kuetgens, U. (1996). High resolution x-ray absorption spectroscopy with absolute energy calibration for the determination of absorption edge energies. Review of Scientific Instruments. https://doi.org/10.1063/1.1146657
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.