Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 701

The DOI matches its Crossref record.

Precision lattice constant determination

Open access
Bond, W. L.·1960·Acta Crystallographica

Abstract

A single crystal method of lattice constant determination is presented by Bond in which the several errors are minimized or corrections computed. The apparatus measures the angle between two reflecting positions of the crystal. With nearly perfect crystals the lattice constants can be measured to a few parts in a million.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0365110x60001941

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 701

Metadata

Authors
Bond, W. L.
Venue
Acta Crystallographica
Published
1960-10-01
Volume
13
Issue
10
Pages
814-818
ISSN
0365-110X (ISSN-L)
OpenAlex
W2113017370
Cited by
701
References
0
FWCI
5.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precision lattice constant determination. https://app.cochat.ai/papers/10.1107/s0365110x60001941
The paper
Bond, W. L. (1960). Precision lattice constant determination. Acta Crystallographica. https://doi.org/10.1107/s0365110x60001941

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.