The DOI matches its Crossref record.
High-resolution ion mobility measurements
Abstract
Gas phase ion mobility measurements can resolve structural isomers for polyatomic ions and provide information about their geometries. A new experimental apparatus for performing high-resolution ion mobility measurements is described. The apparatus consists of a pulsed laser vaporization/desorption source coupled through an ion gate to a 63-cm-long drift tube. The ion gate is a critical component that prevents the diffusion of neutral species from the source into the drift tube. Ions travel along the drift tube under the influence of a uniform electric field. At the end of the drift tube some of the ions exit through a small aperture. They are focused into a quadrupole mass spectrometer, where they are mass analyzed, and then detected by an off-axis collision dynode and by dual microchannel plates. The apparatus is operated with a drift voltage of up to 14 000 V and a helium buffer gas pressure of around 500 Torr. The resolving power for ion mobility measurements is over an order of magnitude higher than has been achieved using conventional injected-ion drift tube techniques. Examples of the application of the new apparatus in resolving isomers of laser desorbed metallofullerenes, in studying silicon clusters generated by laser vaporization, and in following the isomerization of small nanocrystalline (NaCl)nCl− clusters as a function of temperature, are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Ion mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Ion Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Metadata
- Authors
- Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1997-02-01
- Volume
- 68
- Issue
- 2
- Pages
- 1122-1129
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1988008969
- Cited by
- 299
- References
- 0
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution ion mobility measurements. https://app.cochat.ai/papers/10.1063/1.1147873
- The paper
- Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997). High-resolution ion mobility measurements. Review of Scientific Instruments. https://doi.org/10.1063/1.1147873
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.