Instrumental improvements in optical waveguide light mode spectroscopy for the study of biomolecule adsorption
Open accessThe DOI matches its Crossref record.
Abstract
Optical waveguide light mode spectroscopy (OWLS) is a new technique that is particularly well suited to the in situ study of biomolecule adsorption kinetics on surfaces. Here we describe improvements to a commercial OWLS instrument in order to allow for easy combination with other ex situ surface-characterization methods, such as x-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry, and atomic force microscopy. Further, the problem of contamination of the waveguide surface arising from the use of silicone in the flow-through cuvette with which biomolecules are brought into contact with the adsorbing surface had to be resolved, as it greatly altered the wetting and adsorption properties of the waveguide. Finally, through physical vapor deposition of thin, nanosized layers of titanium oxide onto the waveguide layer, it is possible to simulate the surface properties of oxide-covered titanium implant surfaces. However, scanning angle constraints set by the mechanics of the commercial instrument must be borne in mind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
“termination of the adsorbed mass and the number of adsorbed molecules [123] using de Feijter’s formula [111, 112].”
BackgroundMethodThe Density and Refractive Index of Adsorbing Protein Layers
Vörös, J. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.030072 · Cited by 752
Kenausis, G. L., Vörös, J., Elbert, D. L., Huang, N., Hofer, R., Ruiz-Taylor, L., Textor, M., Hubbell, J. A., & Spencer, N. D. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp993359m · Cited by 675
Self-citationHöök, F., Vörös, J., Rodahl, M., Kurrat, R., Böni, P., Ramsden, J. J., Textor, M., Spencer, N. D., Tengvall, P., Gold, J., et al. (2002) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(01)00236-3 · Cited by 671
Self-citationHuang, N.-P., Michel, R., Voros, J., Textor, M., Hofer, R., Rossi, A., Elbert, D. L., Hubbell, J. A., & Spencer, N. D. (2001) · Langmuir · doi:10.1021/la000736+ · Cited by 479
Self-citation
Metadata
- Authors
- Kurrat, R., Textor, M., Ramsden, J. J., Böni, P., & Spencer, N. D.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1997-05-01
- Volume
- 68
- Issue
- 5
- Pages
- 2172-2176
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2044321909
- Cited by
- 89
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Instrumental improvements in optical waveguide light mode spectroscopy for the study of biomolecule adsorption. https://app.cochat.ai/papers/10.1063/1.1148069
- The paper
- Kurrat, R., Textor, M., Ramsden, J. J., Böni, P., & Spencer, N. D. (1997). Instrumental improvements in optical waveguide light mode spectroscopy for the study of biomolecule adsorption. Review of Scientific Instruments. https://doi.org/10.1063/1.1148069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.