The DOI matches its Crossref record.
Poly(l-lysine)-g-poly(ethylene glycol) Layers on Metal Oxide Surfaces: Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption
Abstract
Poly( l -lysine)- g -poly(ethylene glycol) (PLL- g -PEG) is a member of a family of polycationic PEG-grafted copolymers that have been shown to chemisorb on anionic surfaces, including various metal oxide surfaces, providing a high degree of resistance to protein adsorption. PLL- g -PEG-modified surfaces are attractive for a variety of applications including sensor chips for bioaffinity assays and blood-contacting biomedical devices. The analytical and structural properties of PLL- g -PEG adlayers on niobium oxide (Nb 2 O 5 ), tantalum oxide (Ta 2 O 5 ), and titanium oxide (TiO 2 ) surfaces were investigated using reflection−absorption infrared spectroscopy (RAIRS), angle-dependent X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The combined analytical information provides clear evidence for an architecture with the cationic poly( l -lysine) attached electrostatically to the oxide surfaces (charged negatively at physiological pH) and the poly(ethylene oxide) side chains extending out from the surface. The relative intensities of the vibrational modes in the RAIRS spectra and the angle-dependent XPS data point to the PLL backbone being located directly at and parallel to the oxide/polymer interface, whereas the PEG chains are preferentially oriented in the direction perpendicular to the surface. Both positive and negative ToF-SIMS spectra are dominated by PEG-related secondary ion fragments with strongly reduced metal (oxide) intensities pointing to an (almost) complete coverage by the densely packed PEG comblike grafts. The three different transition metal oxide surfaces with isoelectric points well below 7 were found to behave very similarly, both in respect to the kinetics of the polymer adlayer adsorption and properties as well as in terms of protein resistance of the PLL- g -PEG-modified surface. Adsorption of serum and fibrinogen was evaluated using the OWLS optical planar waveguide technique. The amount of human serum adsorbed on the modified surfaces was consistently below the detection limit of the optical sensor technique used (<1−2 ng cm - 2 ), and fibrinogen adsorption was reduced by 96−98% in comparison to the nonmodified (bare) oxide surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Novel Strategies for the Prevention and Treatment of Biofilm Related Infections
Chen, M., Yu, Q., & Sun, H. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918488 · Cited by 429
Metadata
- Authors
- Huang, N.-P., Michel, R., Voros, J., Textor, M., Hofer, R., Rossi, A., Elbert, D. L., Hubbell, J. A., & Spencer, N. D.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-21
- Volume
- 17
- Issue
- 2
- Pages
- 489-498
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2045691265
- Cited by
- 479
- References
- 0
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly(l-lysine)-g-poly(ethylene glycol) Layers on Metal Oxide Surfaces: Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption. https://app.cochat.ai/papers/10.1021/la000736+
- The paper
- Huang, N.-P., Michel, R., Voros, J., Textor, M., Hofer, R., Rossi, A., Elbert, D. L., Hubbell, J. A., & Spencer, N. D. (2001). Poly(l-lysine)-g-poly(ethylene glycol) Layers on Metal Oxide Surfaces: Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption. Langmuir. https://doi.org/10.1021/la000736%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.