The DOI matches its Crossref record.
Work function of indium tin oxide transparent conductor measured by photoelectron spectroscopy
Abstract
We used ultraviolet and x-ray photoelectron spectroscopy (XPS) and (UPS) techniques to directly measure absolute values of vacuum work function of indium tin oxide (ITO) thin films. We obtained a work function of 4.4–4.5 eV which is lower than the commonly cited value. These values do not change substantially by heating and Ar ion sputtering. The atomic concentrations of each element in ITO, measured with XPS, are also quite stable under heat treatment and ion sputtering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clavero, C. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.238 · Cited by 2,762
Transparent Conducting Oxides—An Up-To-Date Overview
Stadler, A. (2012) · Materials · doi:10.3390/ma5040661 · Cited by 448
Fast and Sensitive Colloidal Quantum Dot Mid-Wave Infrared Photodetectors
Ackerman, M. M., Tang, X., & Guyot-Sionnest, P. (2018) · ACS Nano · doi:10.1021/acsnano.8b03425 · Cited by 272
Metadata
- Authors
- Park, Y., Choong, V., Gao, Y., Hsieh, B. R., & Tang, C. W.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1996-05-06
- Volume
- 68
- Issue
- 19
- Pages
- 2699-2701
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2015357699
- Cited by
- 690
- References
- 0
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Work function of indium tin oxide transparent conductor measured by photoelectron spectroscopy. https://app.cochat.ai/papers/10.1063/1.116313
- The paper
- Park, Y., Choong, V., Gao, Y., Hsieh, B. R., & Tang, C. W. (1996). Work function of indium tin oxide transparent conductor measured by photoelectron spectroscopy. Applied Physics Letters. https://doi.org/10.1063/1.116313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.