The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Controlled vertical manipulation of single CO molecules with the scanning tunneling microscope: A route to chemical contrast
Abstract
A reliable procedure for controlled vertical transfer of single CO molecules between a Cu(111) surface and a scanning tunneling microscope tip and vice versa is demonstrated. It is shown that with a tip having a single CO molecule at its apex, chemical contrast is achieved allowing distinction of adsorbed CO molecules and oxgen atoms, which look very similar to the bare metal tip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Theory and Application for the Scanning Tunneling Microscope
Tersoff, J., & Hamann, D. R. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.1998 · Cited by 2,554
The Chemical Physics of Solid Surfaces and Heterogeneous Catalysis
(1988) · The Chemical Physics of Solid Surfaces · doi:10.1016/b978-0-444-42782-3.50001-7 · Cited by 1,333
Imaging standing waves in a two-dimensional electron gas
Crommie, M. F., Lutz, C. P., & Eigler, D. M. (1993) · Nature · doi:10.1038/363524a0 · Cited by 1,276
Atomic and Molecular Manipulation with the Scanning Tunneling Microscope
Stroscio, J. A., & Eigler, D. M. (1991) · Science · doi:10.1126/science.254.5036.1319 · Cited by 1,131
An atomic switch realized with the scanning tunnelling microscope
Eigler, D. M., Lutz, C. P., & Rudge, W. E. (1991) · Nature · doi:10.1038/352600a0 · Cited by 785
Direct observation of standing wave formation at surface steps using scanning tunneling spectroscopy
Hasegawa, Y., & Avouris, P. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1071 · Cited by 631
Meyer, G. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147080 · Cited by 221
Self-citationControlled Atom by Atom Restructuring of a Metal Surface with the Scanning Tunneling Microscope
Meyer, G., Bartels, L., Zöphel, S., Henze, E., & Rieder, K. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1512 · Cited by 92
Self-citationNeu, B., Meyer, G., & Rieder, K. (1995) · Modern Physics Letters B · doi:10.1142/s0217984995000929 · Cited by 50
Self-citation
Cited by
An sp-hybridized molecular carbon allotrope, cyclo[18]carbon
Kaiser, K., Scriven, L. M., Schulz, F., Gawel, P., Gross, L., & Anderson, H. L. (2019) · Science · doi:10.1126/science.aay1914 · Cited by 673
Bistability in Atomic-Scale Antiferromagnets
Loth, S., Baumann, S., Lutz, C. P., Eigler, D. M., & Heinrich, A. J. (2012) · Science · doi:10.1126/science.1214131 · Cited by 636
Bond-Order Discrimination by Atomic Force Microscopy
Gross, L., Mohn, F., Moll, N., Schuler, B., Criado, A., Guitián, E., Peña, D., Gourdon, A., & Meyer, G. (2012) · Science · doi:10.1126/science.1225621 · Cited by 537
Self-citationHeinrich, A. J., Lutz, C. P., Gupta, J. A., & Eigler, D. M. (2002) · Science · doi:10.1126/science.1076768 · Cited by 453
The qPlus sensor, a powerful core for the atomic force microscope
Giessibl, F. J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5052264 · Cited by 358
Metadata
- Authors
- Bartels, L., Meyer, G., & Rieder, K.-H.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1997-07-14
- Volume
- 71
- Issue
- 2
- Pages
- 213-215
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1964565139
- Cited by
- 408
- References
- 10
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlled vertical manipulation of single CO molecules with the scanning tunneling microscope: A route to chemical contrast. https://app.cochat.ai/papers/10.1063/1.119503
- The paper
- Bartels, L., Meyer, G., & Rieder, K.-H. (1997). Controlled vertical manipulation of single CO molecules with the scanning tunneling microscope: A route to chemical contrast. Applied Physics Letters. https://doi.org/10.1063/1.119503
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.