CoChat

Scanning nonlinear dielectric microscopy with nanometer resolution

Cho, Yasuo, Kazuta, Satoshi, Matsuura, Kaori · 1999 · Applied Physics Letters
Cited by 178

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A very high-resolution scanning nonlinear dielectric microscope was developed for the observation of ferroelectric polarization. We demonstrate that the resolution of the microscope is of a nanometer order by measurement of the c–c domain wall of a BaTiO3 single crystal, and that this microscope is very useful not only for the domain observation of ferroelectric bulk material but also for that of thin films.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.125165

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 178

Metadata

Authors
Cho, Y., Kazuta, S., & Matsuura, K.
Venue
Applied Physics Letters
Published
1999-11-01
Volume
75
Issue
18
Pages
2833-2835
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2094900316
Cited by
178
References
1
FWCI
14.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Scanning nonlinear dielectric microscopy with nanometer resolution. https://app.cochat.ai/papers/10.1063/1.125165
The paper
Cho, Y., Kazuta, S., & Matsuura, K. (1999). Scanning nonlinear dielectric microscopy with nanometer resolution. Applied Physics Letters. https://doi.org/10.1063/1.125165

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.