Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The inhomogeneity of tissue structure greatly affects the sensitivity of tissue oxygenation measurement by reflectance near-infrared spectroscopy. In this study, we investigated the influence of a fat layer on muscle oxygenation measurement by in vivo tests and Monte Carlo simulation, and we propose a method for correcting the influence. In the simulation, a three-dimensional model consisting of the epidermis, dermis, fat, and muscle layers was used. In in vivo tests, measurement sensitivity was examined by measuring oxygen consumption of the forearm muscle and the peak-to-peak variation of oxygenation in periodic exercise tests on the vastus lateralis using a newly developed multisensor type of tissue oximeter. Fat layer thickness was also measured by ultrasonography. The correction curve of measurement sensitivity against fat layer thickness was obtained from the results of simulation and in vivo tests. The values of corrected oxygen consumption were almost the same and had less variation between individuals (0.13±0.02 ml 100 g−1 min−1) than did the uncorrected values (0.08±0.04 ml 100 g−1 min−1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484
Homma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Chin, L. M. K., Kowalchuk, J. M., Barstow, T. J., Kondo, N., Amano, T., Shiojiri, T., & Koga, S. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01216.2010 · Cited by 106
Koga, S., Poole, D. C., Fukuoka, Y., Ferreira, L. F., Kondo, N., Ohmae, E., & Barstow, T. J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00101.2011 · Cited by 92
Gurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
Metadata
- Authors
- Niwayama, M., Lin, L., Shao, J., Kudo, N., & Yamamoto, K.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2000-12-01
- Volume
- 71
- Issue
- 12
- Pages
- 4571-4575
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2047301560
- Cited by
- 94
- References
- 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer. https://app.cochat.ai/papers/10.1063/1.1322578
- The paper
- Niwayama, M., Lin, L., Shao, J., Kudo, N., & Yamamoto, K. (2000). Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer. Review of Scientific Instruments. https://doi.org/10.1063/1.1322578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.