The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Responsive biomimetic hydrogel valve for microfluidics
Abstract
A biomimetic hydrogel valve capable of directional flow control in response to the local fluid environment in microfluidic channels is described. The valve consists of a pair of photopolymerized hydrogel bistrips with different pH sensitivities, and becomes activated or deactivated reversibly based on local pH as a result of volume and shape changes. When activated at pH 8, the valve mimics anatomic venous valves both functionally and structurally, allowing fluid flow in one direction under forward pressure while restricting flow in the opposite direction. At an applied pressure of 0.71 psi, the forward flow rate was 140 μL/min, compared to a backward leakage rate of 2.3 μL/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warwick, R., Williams, P. L., Dyson, M., & Bannister, L. (1985) · The British Journal of Radiology · doi:10.1259/0007-1285-58-694-1029 · Cited by 4,532
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Self-citationTanaka, T., & Fillmore, D. J. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437602 · Cited by 1,626
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Synthesis and Application of Modulated Polymer Gels
Hu, Z., Zhang, X., & Li, Y. (1995) · Science · doi:10.1126/science.269.5223.525 · Cited by 544
Microrobots and micromechanical systems
Trimmer, W. S. N. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87079-9 · Cited by 414
Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
Beebe, D. J., Moore, J. S., Yu, Q., Liu, R. H., Kraft, M. L., Jo, B.-H., & Devadoss, C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250273097 · Cited by 353
Self-citation
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Self-citation
Metadata
- Authors
- Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2001-04-23
- Volume
- 78
- Issue
- 17
- Pages
- 2589-2591
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1985718165
- Cited by
- 262
- References
- 7
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.