High resolution low-temperature superconductivity superconducting quantum interference device microscope for imaging magnetic fields of samples at room temperatures
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have developed a microscope to image weak magnetic fields using submillimeter pickup coils made from conventional low-temperature superconducting niobium wire coupled to the input circuit of a superconducting quantum interference device (SQUID). The pickup coil and the SQUID sensor are mounted in the vacuum space of the cryostat and are thermally anchored to the liquid helium reservoir. A 25 μm thick sapphire window separates the room temperature (RT) sample and the vacuum space. The spacing between the pickup coil and RT sample was typically less than 130 μm. The spatial resolution is limited by the diameter of the pickup coil. The pickup coils are easily interchangeable, allowing us to adapt the SQUID microscope to a variety of different measurements. We have achieved a spatial resolution of 250 μm with a magnetic field sensitivity of 850 fT/Hz1/2 or a spatial resolution of 500 μm with a magnetic field sensitivity of 330 fT/Hz1/2. We have used this instrument to measure various biomagnetic and paleomagnetic fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Low Temperature Transfer of ALH84001 from Mars to Earth
Weiss, B. P., Kirschvink, J. L., Baudenbacher, F. J., Vali, H., Peters, N. T., Macdonald, F. A., & Wikswo, J. P. (2000) · Science · doi:10.1126/science.290.5492.791 · Cited by 218
Self-citation
Cited by
Records of an ancient Martian magnetic field in ALH84001
Weiss, B. P., Vali, H., Baudenbacher, F. J., Kirschvink, J. L., Stewart, S. T., & Shuster, D. L. (2002) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(02)00728-8 · Cited by 177
Self-citationHigh Resolution Magnetic Images of Planar Wave Fronts Reveal Bidomain Properties of Cardiac Tissue
Holzer, J. R., Fong, L. E., Sidorov, V. Y., Wikswo, J. P., & Baudenbacher, F. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.049163 · Cited by 33
Self-citationMeasurements of transmembrane potential and magnetic field at the apex of the heart
McBride, K. K., Roth, B. J., Sidorov, V. Y., Wikswo, J. P., & Baudenbacher, F. J. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.08.040 · Cited by 21
Self-citationSQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field
Wikswo, J. P. (2004) · Physics Today · doi:10.1063/1.1688056 · Cited by 13
Self-citation
Metadata
- Authors
- Baudenbacher, F., Peters, N. T., & Wikswo, J. P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2002-03-01
- Volume
- 73
- Issue
- 3
- Pages
- 1247-1254
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2105525130
- Cited by
- 51
- References
- 1
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.