SQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The uninformed reader might be misled into believing that optical magnetometers (see Physics Today, Physics Today 0031-9228 56 7 2003 21 https://doi.org/10.1063/1.1603066. July 2003, page 21 ) will soon displace SQUIDs for biomagnetic measurements. I have spent 30 years using superconducting quantum interference device (SQUID) magnetometers and miniature induction-coil magnetometers to measure biomagnetic fields with ever-increasing spatial resolution. Several significant obstacles lie between optical magnetometers and high-resolution measurements of the brain’s magnetic field. 1 1. I. K. Kominis, T. W. Kornack, J. C. Allred, M. V. Romalis, Nature 422, 596 (2003). https://doi.org/10.1038/nature01484 Several points are worthy of careful analysis. First, the typically reported sensitivity of SQUIDs, 1 fT/Hz1/2, is not a fundamental limit set by the Josephson effect, but a practical one. One must consider thermal (Johnson and thermoelectric) noise within the Dewar flask and the object being studied; the object’s intrinsic noise—for example, brain noise (thermal currents and background neural activity within the brain); fluctuations of magnetic shields; environmental magnetic noise; the desired spatial resolution; and the dynamic range of the electronics. SQUID sensitivities of nearly 10−17 T/Hz1/2 have been reported. 2 2. M. B. Simmonds, W. A. Fertig, R. P. Giffard, IEEE Trans. Magn. 15, 478 (1979); https://doi.org/10.1109/TMAG.1979.1060155 J. Tate, S. B. Felch, B. Cabrera, Phys. Rev. B 42, 7885 (1990). https://doi.org/10.1103/PhysRevB.42.7885 With the exception of SQUID microscopy, more sensitive SQUIDs are not generally needed for biomagnetism, because the existing ones have reached the noise floor set by the Dewar, the object being studied, or the environment.Because superconducting pickup coils can either trap or exclude magnetic flux, SQUIDs have the tremendous advantage of being able to measure femtotesla magnetic fields in the presence of tesla-strength steady fields and microtesla time-varying ones. A well-balanced SQUID gradiometer operating in the geomagnetic field can achieve a common mode rejection of up to 107. Electronic gradiometry allows high-quality SQUID recordings of the adult and fetal magnetoencephalogram (MEG) in unshielded laboratories. 3 3. J. Vrba, S. E. Robinson, Methods 25, 249 (2001). https://doi.org/10.1006/meth.2001.1238 The magnetic shields and cancellation coils needed for the Kominis optical magnetometer reduce the external magnetic field by a factor of 106, four orders of magnitude greater than the shielding factor of approximately 200 for the standard magnetically shielded rooms often used for biomagnetic measurements. That both the optical magnetometer and the object producing the magnetic signals have to operate in such a low magnetic field is a severe practical constraint, such that Kominis and colleagues 1 1. I. K. Kominis, T. W. Kornack, J. C. Allred, M. V. Romalis, Nature 422, 596 (2003). https://doi.org/10.1038/nature01484 suggest using superconducting magnetic shields to reduce “the overall noise of the magnetometer.”The most important point missed in the discussion of the recent optical advance is that the ability of any magnetometer to discriminate between two adjacent sources, such as a pair of cortical columns (modules), is determined not only by the size of the magnetometer but also by the cortex–magnetometer separation. A good rule of thumb is that the magnetometer size and the source-to-sample distance should be approximately equal, lest the spatial resolution of a small magnetometer be blurred by a large separation. To record the MEG from the intact brain, the cortex-to-magnetometer separation would be at least 1 cm—the skull thickness. Hence, millimeter-sized magnetometers would provide little additional benefit.To be competitive with current commercial SQUID MEG instruments, the magnetic field would have to be measured at about 300 separate locations on the surface of the skull, and ideally more than one field component would be measured. At a minimum, the field component perpendicular to the skull would be needed, which means that each normal-component magnetometer would be measuring the field in a different direction, complicating the control and readouts for optical magnetometers. Although multichannel SQUID MEG systems can already localize a single cortical dipole current source to within a millimeter, many clinically significant MEG sources are distributed over 10 cm2 or more. An optical magnetometer with submillimeter spatial resolution could be used effectively only if the cortical column being measured were a comparable distance from the magnetometer. That would require removal of the skull—readily achieved in whole-animal or brain-slice preparations, but not achieved noninvasively. Finally, the optical magnetometer operates in a 180°C oven, and noiselessly protecting a 37°C brain from a hot magnetometer may be harder than from a −270°C SQUID, since
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A promising perspective is the in vivo application of superparamagnetic markers, especially if the current research into breast cancer detection proves successful [51].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [51]
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Signal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716
Determination of the Cooper-pair mass in niobium
Tate, J., Felch, S. B., & Cabrera, B. (1990) · Physical review. B, Condensed matter · doi:10.1103/physrevb.42.7885 · Cited by 52
Baudenbacher, F., Peters, N. T., & Wikswo, J. P. (2002) · Review of Scientific Instruments · doi:10.1063/1.1448142 · Cited by 51
Self-citationBaudenbacher, F., Fong, L. E., Holzer, J. R., & Radparvar, M. (2003) · Applied Physics Letters · doi:10.1063/1.1572968 · Cited by 50
Performance of a resonant input SQUID amplifier system
Simmonds, M., Fertig, W., & Giffard, R. (1979) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1979.1060155 · Cited by 35
New Atomic Magnetometer Achieves Subfemtotesla Sensitivity
Fitzgerald, R. (2003) · Physics Today · doi:10.1063/1.1603066 · Cited by 10
Cited by
Presentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Highly sensitive magnetometers—a review
Robbes, D. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.11.023 · Cited by 177
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
“Although elimination of cryogenics should be advantageous in system handling and also economically, such magnetometers and gradiometers suffer from other problems [50].”
BackgroundTarduno, J. A., Cottrell, R. D., & Smirnov, A. V. (2006) · Reviews of Geophysics · doi:10.1029/2005rg000189 · Cited by 160
“…Tarduno et al.: PALEOMAGNETISM OF SINGLE SILICATE CRYSTALS 6 of 31 RG1002 magnetometer [Kominis et al., 2003; Fitzgerald, 2003], notwithstanding debate on the subject [e.g., Wikswo, 2004], might ultimately assist efforts to read the paleomagnetic signal of the weakest silicate crystals.”
BackgroundPaleomagnetic analysis using SQUID microscopy
Weiss, B. P., Lima, E. A., Fong, L. E., & Baudenbacher, F. J. (2007) · Journal of Geophysical Research Atmospheres · doi:10.1029/2007jb004940 · Cited by 112
“[2] Superconducting quantum interference devices (SQUIDs) are the most sensitive magnetometers available for making quantitative measurements of magnetic fields [Braginski and Clarke, 2004; Wikswo, 2004].”
Metadata
- Authors
- Wikswo, J. P.
- Affiliations
- Vanderbilt University (US)
- Corresponding author
- Wikswo, John P.
- ORCID
- Wikswo, John P.
- Venue
- Physics Today
- Publisher
- AIP Publishing
- Published
- 2004-02-01
- Volume
- 57
- Issue
- 2
- Pages
- 15-17
- ISSN
- 0031-9228 (ISSN-L)
- 1945-0699
- OpenAlex
- W2077971956
- Cited by
- 13
- References
- 7
- Citations by year
- 2019: 2 · 2018: 1 · 2015: 1 · 2014: 1
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics Today (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- SQUID magnetometer, brain magnetic fields, optical magnetometer, SQUID sensitivity, thermal noise, spatial resolution, dynamic range, SQUID microscopy, noise floor, magnetic shielding, neural activity detection, magnetic resonance imaging comparison, magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field. https://app.cochat.ai/papers/10.1063/1.1688056
- The paper
- Wikswo, J. P. (2004). SQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field. Physics Today. https://doi.org/10.1063/1.1688056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.