Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Coherent vibrational motion in metal particles: Determination of the vibrational amplitude and excitation mechanism

Hartland, Gregory V.·2002·The Journal of Chemical Physics

Abstract

Ultrafast laser excitation of metal particles coherently excites the symmetric breathing mode. This changes the electron density in the particle, which produces a periodic redshift in the position of the plasmon band. In this paper transient absorption data recorded over a range of wavelengths are analyzed to determine the amplitude of the breathing motion for 24.2 nm radius Au particles. The results are compared to a model calculation where the expansion coordinate is treated as a damped harmonic oscillator and the driving force is thermal expansion due to lattice heating (the temperature rise is determined from the energy absorbed by the sample). The only adjustable parameters in these calculations are the dephasing time of the oscillations and the time scale for energy transfer to the solvent. The experimental and calculated vibrational amplitudes are in excellent agreement, which shows that all the absorbed energy goes into expansion. However, the phases of the calculated and experimental traces do not match. The calculations can be brought into almost perfect agreement with the experimental results by including hot-electron pressure effects in the coefficient for thermal expansion of the particles. This contribution is significant in our experiments because laser excitation initially creates a very high electronic temperature. A simple expression for the time dependence of the transient absorption signal is also derived that explicitly accounts for sample polydispersity. In this expression the beat period is related to the mean radius, and the damping time to the mean radius and the width of the size distribution. Thus, time-resolved laser experiments can be used to obtain accurate information about the size distribution of metal particle samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1469021

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 177

Metadata

Authors
Hartland, G. V.
Venue
The Journal of Chemical Physics
Published
2002-05-08
Volume
116
Issue
18
Pages
8048-8055
ISSN
  • 0021-9606 (ISSN-L)
  • 1089-7690
OpenAlex
W2064749969
Cited by
177
References
1
FWCI
6.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coherent vibrational motion in metal particles: Determination of the vibrational amplitude and excitation mechanism. https://app.cochat.ai/papers/10.1063/1.1469021
The paper
Hartland, G. V. (2002). Coherent vibrational motion in metal particles: Determination of the vibrational amplitude and excitation mechanism. The Journal of Chemical Physics. https://doi.org/10.1063/1.1469021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.