The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Protein detection by optical shift of a resonant microcavity
Abstract
We present an optical biosensor with unprecedented sensitivity for detection of unlabeled molecules. Our device uses optical resonances in a dielectric microparticle (whispering gallery modes) as the physical transducing mechanism. The resonances are excited by evanescent coupling to an eroded optical fiber and detected as dips in the light intensity transmitted through the fiber at different wavelengths. Binding of proteins on the microparticle surface is measured from a shift in resonance wavelength. We demonstrate the sensitivity of our device by measuring adsorption of bovine serum albumin and we show its use as a biosensor by detecting streptavidin binding to biotin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Concentration of hydroxyl groups on the surface of amorphous silicas
Zhuravlev, L. T. (1987) · Langmuir · doi:10.1021/la00075a004 · Cited by 1,032
Advances in surface plasmon resonance biosensor analysis
Rich, R. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00054-3 · Cited by 665
Three-Dimensional Structure of Human Serum Albumin
Carter, D. C., He, X.-M., Munson, S. H., Twigg, P. D., Gernert, K. M., Broom, M. B., & Miller, T. Y. (1989) · Science · doi:10.1126/science.2727704 · Cited by 602
Biospecific interaction analysis using biosensor technology
Malmqvist, M. (1993) · Nature · doi:10.1038/361186a0 · Cited by 532
Biosensors--Sense and Sensitivity
Turner, A. P. F. (2000) · Science · doi:10.1126/science.290.5495.1315 · Cited by 524
Zammatteo, N., Jeanmart, L., Hamels, S., Courtois, S., Louette, P., Hevesi, L., & Remacle, J. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4515 · Cited by 308
Karlsson, R., & Stahlberg, R. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1350 · Cited by 280
Excitation of resonances of microspheres on an optical fiber
Serpengüzel, A., Griffel, G., & Arnold, S. (1995) · Optics Letters · doi:10.1364/ol.20.000654 · Cited by 265
Self-citationImplementing surface plasmon resonance biosensors in drug discovery
Myszka, D. G., & Rich, R. L. (2000) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(00)00288-1 · Cited by 236
Protein Interaction Methods-Toward an Endgame
Mendelsohn, A. R., & Brent, R. (1999) · Science · doi:10.1126/science.284.5422.1948 · Cited by 136
Malmqvist, M., & Karlsson, R. (1997) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(97)80077-4 · Cited by 131
Karlsson, R., Kullman-Magnusson, M., Hämäläinen, M., Remaeus, A., Andersson, K., Borg, P., Gyzander, E., & Deinum, J. (2000) · Analytical Biochemistry · doi:10.1006/abio.1999.4406 · Cited by 126
Cited by
Vahala, K. J. (2003) · Nature · doi:10.1038/nature01939 · Cited by 4,878
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Whispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
Self-citationMicro-combs: A novel generation of optical sources
Pasquazi, A., Peccianti, M., Razzari, L., Moss, D. J., Coen, S., Erkintalo, M., Chembo, Y. K., Hansson, T., Wabnitz, S., Del’Haye, P., et al. (2018) · Physics Reports · doi:10.1016/j.physrep.2017.08.004 · Cited by 1,074
Metadata
- Authors
- Vollmer, F., Braun, D., Libchaber, A., Khoshsima, M., Teraoka, I., & Arnold, S.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2002-05-27
- Volume
- 80
- Issue
- 21
- Pages
- 4057-4059
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2015665105
- Cited by
- 903
- References
- 12
- FWCI
- 24.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.