Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 570

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Micromechanics of actuation of ionic polymer-metal composites

Nemat-Nasser, Sia · 2002 · Journal of Applied Physics

Abstract

Ionic polymer-metal composites (IPMCs) consist of a polyelectrolyte membrane (usually, Nafion or Flemion) plated on both faces by a noble metal, and is neutralized with certain counter ions that balance the electrical charge of the anions covalently fixed to the backbone membrane. In the hydrated state (or in the presence of other suitable solvents), the composite is a soft actuator and sensor. Its coupled electrical-chemical-mechanical response depends on: (1) the chemical composition and structure of the backbone ionic polymer; (2) the morphology of the metal electrodes; (3) the nature of the cations; and (4) the level of hydration (solvent saturation). A systematic experimental evaluation of the mechanical response of both metal-plated and bare Nafion and Flemion in various cation forms and various water saturation levels has been performed in the author’s laboratories at the University of California, San Diego. By examining the measured stiffness of the Nafion-based composites and the corresponding bare Nafion, under a variety of conditions, I have sought to develop relations between internal forces and the resulting stiffness and deformation of this class of IPMCs. Based on these and through a comparative study of the effects of various cations on the material’s stiffness and response, I have attempted to identify potential micromechanisms responsible for the observed electromechanical behavior of these materials, model them, and compare the model results with experimental data. A summary of these developments is given in the present work. First, a micromechanical model for the calculation of the Young modulus of the bare Nafion or Flemion in various ion forms and water saturation levels is given. Second, the bare-polymer model is modified to include the effect of the metal plating, and the results are applied to calculate the stiffness of the corresponding IPMCs, as a function of the solvent uptake. Finally, guided by the stiffness modeling and data, the actuation of the Nafion-based IPMCs is micromechanically modeled. Examples of the model results are presented and compared with the measured data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1495888

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 570

Metadata

Authors
Nemat-Nasser, S.
Venue
Journal of Applied Physics
Published
2002-09-01
Volume
92
Issue
5
Pages
2899-2915
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2143167829
Cited by
570
References
22
FWCI
19.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.