The DOI matches its Crossref record.
Mass sensing of adsorbed molecules in sub-picogram sample with ultrathin silicon resonator
Open accessAbstract
Ultrathin single-crystalline silicon cantilevers with a thickness of 170 nm as a resonating sensor are applied to mass sensing. The hydrogen storage capacity of a small amount of carbon nanotubes (CNTs), which were mounted on an ultrathin resonator by a manipulator, is measured from the resonant frequency change. The resonator is annealed in ultrahigh vacuum to clean the surface and increase the quality factor, and exposed to oxygen gas to oxidize the surface for long-term stability. The resonator can be electrostatically actuated, and the vibration is measured by a laser Doppler vibrometer in ultrahigh vacuum. The mass of the CNTs is determined by the difference of resonant frequencies before and after mounting the CNTs, and the hydrogen storage capacity is determined from the frequency change after exposure to high-pressure hydrogen as well. The obtained hydrogen storage capacitance is 1.6%–6.0%. The available mass resolution and the achieved stability of the resonance of the 170-nm-thick resonator are below 10−18 g and 5 Hz/days, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 695
Ultrasensitive Mass Sensing with a Nanotube Electromechanical Resonator
Lassagne, B., Garcia-Sanchez, D., Aguasca, A., & Bachtold, A. (2008) · Nano Letters · doi:10.1021/nl801982v · Cited by 407
Metadata
- Authors
- Ono, T., Li, X., Miyashita, H., & Esashi, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2003-03-01
- Volume
- 74
- Issue
- 3
- Pages
- 1240-1243
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2085393286
- Cited by
- 170
- References
- 0
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass sensing of adsorbed molecules in sub-picogram sample with ultrathin silicon resonator. https://app.cochat.ai/papers/10.1063/1.1536262
- The paper
- Ono, T., Li, X., Miyashita, H., & Esashi, M. (2003). Mass sensing of adsorbed molecules in sub-picogram sample with ultrathin silicon resonator. Review of Scientific Instruments. https://doi.org/10.1063/1.1536262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.