The DOI matches its Crossref record.
Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications
Abstract
We have fabricated a series of highly sensitive spin valve sensors on a micron scale that successfully detected the presence of a single superparamagnetic bead (Dynabeads M-280, 2.8 μm in diameter), and thus showed suitability for identifying biomolecules labeled by such magnetic beads. By polarizing the magnetic microbead on a spin valve sensor with a dc magnetic field and modulating its magnetization with an orthogonal ac magnetic field, we observed a magnetoresistance (MR) signal reduction caused by the magnetic dipole field from the bead that partially cancelled the applied fields to the spin valve. A lock-in technique was used to measure a voltage signal due to the MR reduction. A signal of 1.2 mV rms or 5.2 mΩ of resistance reduction was obtained from a 3 μm wide sensor and a signal of 3.8 mV rms or 11.9 mΩ from a 2.5 μm wide sensor. Micromagnetic simulations were also performed for the spin valve sensors with a single bead and gave results consistent with experiments. Further experiments and simulations suggested that these sensors or their variations can detect 1–10 Co nanoparticles with a diameter of ∼11 nm, and are suitable for DNA fragment detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monodisperse MFe2O4 (M = Fe, Co, Mn) Nanoparticles
Sun, S., Zeng, H., Robinson, D. B., Raoux, S., Rice, P. M., Wang, S. X., & Li, G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0380852 · Cited by 3,441
Self-citationOleic acid coating on the monodisperse magnetite nanoparticles
Zhang, L., He, R., & Gu, H.-C. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.05.023 · Cited by 994
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Self-citationHydrothermal Treatment of Tannin: A Route to Porous Metal Oxides and Metal/Carbon Hybrid Materials
Braghiroli, F., Fierro, V., Szczurek, A., Gadonneix, P., Ghanbaja, J., Parmentier, J., Medjahdi, G., & Celzard, A. (2017) · Inorganics · doi:10.3390/inorganics5010007 · Cited by 25
Kim, J. K., Basavaraja, C., Umashankar, M., & Huh, D. S. (2016) · Polymer · doi:10.1016/j.polymer.2016.01.052 · Cited by 11
Metadata
- Authors
- Li, G., Joshi, V., White, R. L., Wang, S. X., Kemp, J. T., Webb, C., Davis, R. W., & Sun, S.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2003-05-15
- Volume
- 93
- Issue
- 10
- Pages
- 7557-7559
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2124483640
- Cited by
- 221
- References
- 0
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications. https://app.cochat.ai/papers/10.1063/1.1540176
- The paper
- Li, G., Joshi, V., White, R. L., Wang, S. X., Kemp, J. T., Webb, C., Davis, R. W., & Sun, S. (2003). Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications. Journal of Applied Physics. https://doi.org/10.1063/1.1540176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.