Monolithic low-transition-temperature superconducting magnetometers for high resolution imaging magnetic fields of room temperature samples
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have developed a monolithic low-temperature superconducting quantum interference device (SQUID) magnetometer and incorporated the device in a scanning microscope for imaging magnetic fields of room temperature samples. The instrument has a ∼100 μm spatial resolution and a 1.4 pT/Hz1/2 field sensitivity above a few hertz. We discuss design constraints on and potential applications of the SQUID microscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Records of an ancient Martian magnetic field in ALH84001
Weiss, B. P., Vali, H., Baudenbacher, F. J., Kirschvink, J. L., Stewart, S. T., & Shuster, D. L. (2002) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(02)00728-8 · Cited by 177
Self-citation
Cited by
Scalable Spin Squeezing for Quantum-Enhanced Magnetometry with Bose-Einstein Condensates
Muessel, W., Strobel, H., Linnemann, D., Hume, D. B., & Oberthaler, M. K. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.103004 · Cited by 254
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63
Measurements of transmembrane potential and magnetic field at the apex of the heart
McBride, K. K., Roth, B. J., Sidorov, V. Y., Wikswo, J. P., & Baudenbacher, F. J. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.08.040 · Cited by 21
Self-citationSQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field
Wikswo, J. P. (2004) · Physics Today · doi:10.1063/1.1688056 · Cited by 13
Metadata
- Authors
- Baudenbacher, F., Fong, L. E., Holzer, J. R., & Radparvar, M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2003-05-19
- Volume
- 82
- Issue
- 20
- Pages
- 3487-3489
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2039173298
- Cited by
- 50
- References
- 1
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.