Ultraviolet diffraction limited nanosurgery of live biological tissues
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A laser nanodissection system for in vivo and in situ biological tissues is presented. A pulsed laser beam operating at a wavelength of 355 nm enables diffraction limited dissection, providing an optimal tool for intracellular nanosurgery. Coupled into a conventional inverted microscope and scanned across a field of up to 100×100 μm2, this optical nanoscalpel performs in vivo photoablation and plasma-induced ablation inside organisms ranging from intracellular organelles to embryos. The system allows the use of conventional microscopy contrasts and methods, fast dissection with up to 1000 shots per second, and simultaneous dissection and imaging. This article outlines an efficient implementation with a small number of components and reports an improvement of this state of the art of plasma-induced ablation technique over previous studies, with a ratio of plasma volume to beam focal volume of 5.2. This offers, e.g., the possibility of writing information directly at the sample location by plasma glass nanopatterning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noack, J., & Vogel, A. (1999) · IEEE Journal of Quantum Electronics · doi:10.1109/3.777215 · Cited by 618
Cited by
Mechanisms of femtosecond laser nanosurgery of cells and tissues
Vogel, A., Noack, J., Hüttman, G., & Paltauf, G. (2005) · Applied Physics B · doi:10.1007/s00340-005-2036-6 · Cited by 1,408
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
Functional regeneration after laser axotomy
Yanik, M. F., Cinar, H., Cinar, H. N., Chisholm, A. D., Jin, Y., & Ben-Yakar, A. (2004) · Nature · doi:10.1038/432822a · Cited by 598
Pulsed Forces Timed by a Ratchet-like Mechanism Drive Directed Tissue Movement during Dorsal Closure
Solon, J., Kaya-Çopur, A., Colombelli, J., & Brunner, D. (2009) · Cell · doi:10.1016/j.cell.2009.03.050 · Cited by 539
Self-citationForces driving epithelial wound healing
Brugués, A., Anon, E., Conte, V., Veldhuis, J. H., Gupta, M., Colombelli, J., Muñoz, J. J., Brodland, G. W., Ladoux, B., & Trepat, X. (2014) · Nature Physics · doi:10.1038/nphys3040 · Cited by 450
Self-citation
Metadata
- Authors
- Colombelli, J., Grill, S. W., & Stelzer, E. H. K.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2004-02-01
- Volume
- 75
- Issue
- 2
- Pages
- 472-478
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2032994551
- Cited by
- 74
- References
- 1
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultraviolet diffraction limited nanosurgery of live biological tissues. https://app.cochat.ai/papers/10.1063/1.1641163
- The paper
- Colombelli, J., Grill, S. W., & Stelzer, E. H. K. (2004). Ultraviolet diffraction limited nanosurgery of live biological tissues. Review of Scientific Instruments. https://doi.org/10.1063/1.1641163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.