Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Amorphous versus Crystalline GeTe Films. III. Electrical Properties and Band Structure

Bahl, S. K., Chopra, K. L.·1970·Journal of Applied Physics

Abstract

Various transport studies have been carried out on amorphous and crystalline GeTe films of 80 Å to 10 μ thickness. Crystalline GeTe has a low resistivity (∼10−4 Ω·cm at 300°K) which increases with temperature slowly and nearly linearly at low temperatures (below ∼300°K) and rapidly at higher temperatures. The hole concentration (N∼1010−1021 cm−3) increases only slightly with temperature. Mobility varies as N−4/3. These results in conjunction with the tunnel-spectroscopy and optical data show that crystalline GeTe is a degenerate (and thus metallic conduction), p-type narrow band gap (∼0.1–0.2 eV) semiconductor with Fermi level ∼0.3–0.5 eV inside the valence band. The linear increase of the susceptibility mass with hole concentration, the constancy of the Hall coefficient up toωLτ=0.35 (ωL=Larmor frequency, τ=collision relaxation time), and the monotonic increase of thermopower with temperature indicate that conduction takes place only in a single valence band. Amorphous GeTe films exhibit activated conduction. The dc resistivity varies from 410° to 77°K as ρ0 exp (Eg/2kT), where Eg is about 0.8 eV and ρ0 is the resistivity of crystalline GeTe films. Ac resistivity decreases with frequency (ω) as ω−n, where n lies between 0.5 and 1.0, depending on the temperature. The activation energy for ac conduction decreases rapidly from the dc value to zero with decreasing temperature as well as increasing frequency. The capacitance of amorphous GeTe at 77°K varies as ω−0.2 while the loss factor is independent of the frequency. With increasing dc field, the linear dependence of current on voltage changes to a power relation Vn, where n varies rapidly from ∼3 to 6 or more in a small range of the applied field. At very high fields, I ∝expβF1/2 (β=constant) is observed. These results, together with the tunnel-spectroscopy, and optical data suggest that amorphous GeTe may be represented as a p-type semiconductor with band gap ∼0.8 eV with exponential tailing of the bands and a continum of localized states in the vicinity (both sides) of the band edges. Conduction takes place by two parallel processes of intrinsic excitation across the band gap, and thermally and/or field-assisted hopping from one localized (trapping) state to another. Dc conduction by hopping at low fields is negligible. At higher fields, trap modified space-charge-limited current flow and Poole-Frenkel effect determine the nonlinear field dependence of current.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1659189

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 222

Metadata

Authors
Bahl, S. K., & Chopra, K. L.
Venue
Journal of Applied Physics
Published
1970-04-01
Volume
41
Issue
5
Pages
2196-2212
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2085117470
Cited by
222
References
1
FWCI
9.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amorphous versus Crystalline GeTe Films. III. Electrical Properties and Band Structure. https://app.cochat.ai/papers/10.1063/1.1659189
The paper
Bahl, S. K., & Chopra, K. L. (1970). Amorphous versus Crystalline GeTe Films. III. Electrical Properties and Band Structure. Journal of Applied Physics. https://doi.org/10.1063/1.1659189

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.