The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
The Topografiner: An Instrument for Measuring Surface Microtopography
Abstract
A noncontacting instrument for measuring the microtopography of metallic surfaces has been developed to the point where the feasibility of constructing a prototype instrument has been demonstrated. The resolution of the preprototype unit is 30 Å perpendicular to the surface and 4000 Å in the plane of the surface. Inherent noise in the perpendicular direction corresponds to 3 Å or one atomic layer. By using a typical field emitter with radius of 100 Å, an ultimate limit of 200 Å would be expected for the horizontal resolution. Topographic maps of an infrared diffraction grating have been measured in order to demonstrate the performance of the instrument in measuring a well characterized surface. The instrument has been shown to conform to the Fowler-Nordheim description of field emission while spaced at the usual operating distances from the surface. When moved to within 30 Å of the surface, its performance is compatible with Simmons' theory of MVM tunneling. In the MVM mode, the instrument is capable of performing a noncontacting measurement of the position of a surface to within about 3 Å. The instrument can be used in surface science experiments to study the density of single and multiple atom steps on single crystal surfaces, adsorption of gases, and processes involving electronic excitations at surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De, M. (1957) · Optica Acta: International Journal of Optics · doi:10.1080/713826071 · Cited by 6,319
Simmons, J. G. (1963) · Journal of Applied Physics · doi:10.1063/1.1702682 · Cited by 4,200
Relation Between Surface Roughness and Specular Reflectance at Normal Incidence
Bennett, H. E., & Porteus, J. O. (1961) · Journal of the Optical Society of America · doi:10.1364/josa.51.000123 · Cited by 1,121
Molecular Vibration Spectra by Inelastic Electron Tunneling
Lambe, J., & Jaklevic, R. C. (1968) · Physical Review · doi:10.1103/physrev.165.821 · Cited by 585
Cited by
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Tunneling through a controllable vacuum gap
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Applied Physics Letters · doi:10.1063/1.92999 · Cited by 1,841
Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
Betzig, E., & Trautman, J. K. (1992) · Science · doi:10.1126/science.257.5067.189 · Cited by 1,808
(1993) · Methods in Experimental Physics · doi:10.1016/s0076-695x(08)x6001-6 · Cited by 1,776
Nanostructured Oxides in Chemistry: Characterization and Properties
Fernández-García, M., Martínez-Arias, A., Hanson, J. C., & Rodriguez, J. A. (2004) · Chemical Reviews · doi:10.1021/cr030032f · Cited by 1,035
Metadata
- Authors
- Young, R., Ward, J., & Scire, F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1972-07-01
- Volume
- 43
- Issue
- 7
- Pages
- 999-1011
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2032971627
- Cited by
- 336
- References
- 4
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Topografiner: An Instrument for Measuring Surface Microtopography. https://app.cochat.ai/papers/10.1063/1.1685846
- The paper
- Young, R., Ward, J., & Scire, F. (1972). The Topografiner: An Instrument for Measuring Surface Microtopography. Review of Scientific Instruments. https://doi.org/10.1063/1.1685846
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.