Performance of a resonant input SQUID amplifier system
The DOI matches its Crossref record.
Abstract
We have demonstrated that the input circuit of a SQUID magnetometer may be resonated at the signal frequency to obtain enhanced sensitivity. The improvement which may be obtained over a narrow bandwidth is limited in principle by the input noise of the SQUID. In practice the sensitivity on resonance is limited by thermal noise, and depends on the temperature and Q of the input circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Superconducting quantum interference device instruments and applications
Fagaly, R. L. (2006) · Review of Scientific Instruments · doi:10.1063/1.2354545 · Cited by 594
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Use of a DC SQUID receiver preamplifier in a low field MRI system
Seton, H. C., Bussell, D. M., Hutchison, J. M. S., & Lurie, D. J. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.403276 · Cited by 28
Metadata
- Authors
- Simmonds, M., Fertig, W., & Giffard, R.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1979-01
- Volume
- 15
- Issue
- 1
- Pages
- 478-481
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2077055169
- Cited by
- 35
- References
- 0
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of a resonant input SQUID amplifier system. https://app.cochat.ai/papers/10.1109/tmag.1979.1060155
- The paper
- Simmonds, M., Fertig, W., & Giffard, R. (1979). Performance of a resonant input SQUID amplifier system. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.1979.1060155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.