The DOI matches its Crossref record.
The Theoretical Resolution Limit of the Electron Microscope
Abstract
The resolving power of the electron microscope and the contrast in the image are calculated for different conditions of focusing, illumination and aperture. These conditions can change the limit of resolution by a factor of about 3. The contrast in the image of an atom is appreciably increased by defocusing and spherical aberration. Nevertheless, the contrast improves when the numerical value of the aberration constant is diminished. The effect of different methods of spherical correction is discussed briefly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
Transmission Electron Microscopy of Shape-Controlled Nanocrystals and Their Assemblies
Wang, Z. L. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp993593c · Cited by 2,137
Chemically sensitive structure-imaging with a scanning transmission electron microscope
Pennycook, S. J., & Boatner, L. A. (1988) · Nature · doi:10.1038/336565a0 · Cited by 735
Z-contrast stem for materials science
Pennycook, S. J. (1989) · Ultramicroscopy · doi:10.1016/0304-3991(89)90173-3 · Cited by 580
Structure and bonding at the atomic scale by scanning transmission electron microscopy
Muller, D. A. (2009) · Nature Materials · doi:10.1038/nmat2380 · Cited by 439
Direct transformation of graphene to fullerene
Chuvilin, A., Kaiser, U., Bichoutskaia, E., Besley, N. A., & Khlobystov, A. N. (2010) · Nature Chemistry · doi:10.1038/nchem.644 · Cited by 417
Simulation of annular dark field stem images using a modified multislice method
Kirkland, E. J., Loane, R. F., & Silcox, J. (1987) · Ultramicroscopy · doi:10.1016/0304-3991(87)90229-4 · Cited by 349
Studying Atomic Structures by Aberration-Corrected Transmission Electron Microscopy
Urban, K. W. (2008) · Science · doi:10.1126/science.1152800 · Cited by 348
Reversible loss of core–shell structure for Ni–Au bimetallic nanoparticles during CO2 hydrogenation
Zhang, X., Han, S., Zhu, B., Zhang, G., Li, X., Gao, Y., Wu, Z., Yang, B., Liu, Y., Baaziz, W., et al. (2020) · Nature Catalysis · doi:10.1038/s41929-020-0440-2 · Cited by 347
The principles and interpretation of annular dark-field Z-contrast imaging
Nellist, P. D., & Pennycook, S. J. (2000) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(00)80013-0 · Cited by 339
Atomic resolution of lithium ions in LiCoO2
Shao-Horn, Y., Croguennec, L., Delmas, C., Nelson, E. C., & O'Keefe, M. A. (2003) · Nature Materials · doi:10.1038/nmat922 · Cited by 273
The physical and chemical properties of heteronanotubes
Ayala, P., Arenal, R., Loiseau, A., Rubio, A., & Pichler, T. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.1843 · Cited by 259
Z-contrast Imaging in an Aberration-corrected Scanning Transmission Electron Microscope
Pennycook, S. J., Rafferty, B., & Nellist, P. D. (2000) · Microscopy and Microanalysis · doi:10.1017/s1431927602000594 · Cited by 148
Metadata
- Authors
- Scherzer, O.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1949-01-01
- Volume
- 20
- Issue
- 1
- Pages
- 20-29
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2048380342
- Cited by
- 915
- References
- 0
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.