The DOI matches its Crossref record.
A Direct Method of Determining Preferred Orientation of a Flat Reflection Sample Using a Geiger Counter X-Ray Spectrometer
Abstract
A new reflection method is described for determining pole figures of flat samples with a Geiger counter x-ray spectrometer. The chief advantage of the method is that the experimental data may be used directly without corrections for changes in geometry during rotation of the sample. Beginning from an initial position identical with the usual reflection arrangement the sample is rotated about an axis defined by the intersection of the sample surface with the plane of the spectrometer. During this motion a randomly oriented sample of sufficient thickness will yield a constant counting rate because the absorption and effective scattering volume of the sample remain unchanged. As a result, no correction formula is required. The experimental arrangement requires three horizontal slits; two are used to collimate the incident beam, and the third is placed in front of the counter. A mathematical analysis of the optical elements of the arrangement is given together with the results from a practical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wenk, H.-R. (2002) · Reviews in Mineralogy and Geochemistry · doi:10.2138/gsrmg.51.1.291 · Cited by 931
Baker, J. L., Jimison, L. H., Mannsfeld, S., Volkman, S., Yin, S., Subramanian, V., Salleo, A., Alivisatos, A. P., & Toney, M. F. (2010) · Langmuir · doi:10.1021/la904840q · Cited by 352
Measurement of Orientation in Polypropylene Film
Wilchinsky, Z. W. (1960) · Journal of Applied Physics · doi:10.1063/1.1735481 · Cited by 263
Suzuki, Y., Duran, H., Akram, W., Steinhart, M., Floudas, G., & Butt, H.-J. (2013) · Soft Matter · doi:10.1039/c3sm50907a · Cited by 118
Manipulating Semicrystalline Polymers in Confinement
Shingne, N., Geuss, M., Thurn-Albrecht, T., Schmidt, H.-W., Mijangos, C., Steinhart, M., & Martín, J. (2017) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.7b05424 · Cited by 8
Metadata
- Authors
- Schulz, L. G.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1949-11-01
- Volume
- 20
- Issue
- 11
- Pages
- 1030-1033
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2004704850
- Cited by
- 825
- References
- 0
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Direct Method of Determining Preferred Orientation of a Flat Reflection Sample Using a Geiger Counter X-Ray Spectrometer. https://app.cochat.ai/papers/10.1063/1.1698268
- The paper
- Schulz, L. G. (1949). A Direct Method of Determining Preferred Orientation of a Flat Reflection Sample Using a Geiger Counter X-Ray Spectrometer. Journal of Applied Physics. https://doi.org/10.1063/1.1698268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.