The DOI matches its Crossref record.
Millimeter-wave, terahertz, and mid-infrared transmissionthrough common clothing
Abstract
This letter reports electromagnetic transmission measurements through cloth samples from eight types of fabrics common in garments and baggage. The transmission at millimeter-wave and terahertz frequencies was measured with a custom ErAs:GaAs tunable photomixing spectrometer. The IR transmission between 3 and 8μm was measured with a Fourier-transform infrared spectrometer. All samples were usefully transparent at millimeter-wave frequencies (up to 300GHz) based on a 3dB criterion, but became progressively opaque at higher frequencies in a highly sample-dependent manner. This is explained by the samples becoming “optically dense” in the THz region, so that the transmission becomes exponentially dependent on sample thickness. The attenuation in the IR region is very high (⩾25dB) except in two samples (rayon and nylon), whose exceptional transparency (e.g., −12dB in nylon) is attributed to pores intrinsic to the material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
THz imaging and sensing for security applications—explosives, weapons and drugs
Federici, J. F., Schulkin, B., Huang, F., Gary, D., Barat, R., Oliveira, F., & Zimdars, D. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/018 · Cited by 1,756
Terahertz quantum-cascade lasers
Williams, B. S. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.166 · Cited by 1,543
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Standoff Detection of Weapons and Contraband in the 100 GHz to 1 THz Region
Appleby, R., & Wallace, H. B. (2007) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2007.908543 · Cited by 575
Tunable, continuous-wave Terahertz photomixer sources and applications
Preu, S., Döhler, G. H., Malzer, S., Wang, L. J., & Gossard, A. C. (2011) · Journal of Applied Physics · doi:10.1063/1.3552291 · Cited by 486
Lee, A. W. M., Wil, B. S., Kumar, S., Hu, Q., & Reno, J. L. (2006) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2006.877220 · Cited by 258
Self-citationWu, T., Rappaport, T. S., & Collins, C. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377587 · Cited by 243
“[79] measured the attenuation of eight common garment materials (wool, linen, leather, denim, naugahyde, silk, nylon, and rayon) with thicknesses less than 2.”
Spectral artifacts from non-uniform samples analyzed by terahertz time-domain spectroscopy
Théberge, F., Châteauneuf, M., Dubois, J., Désilets, S., & Lussier, L.-S. (2009) · Optics Express · doi:10.1364/oe.17.010841 · Cited by 14
Heuristic approach to take up the challenge of terahertz time-domain spectroscopy for biology
Lavancier, M. (2026) · doi:10.70675/ae6227b6zb5e7z43aczb2dcza96e56b2799e · Cited by 3
Metadata
- Authors
- Bjarnason, J. E., Chan, T. L. J., Lee, A. W. M., Celis, M. A., & Brown, E. R.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-07-26
- Volume
- 85
- Issue
- 4
- Pages
- 519-521
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1992139567
- Cited by
- 195
- References
- 0
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.