The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Gate-refreshable nanowire chemical sensors
Abstract
ZnO nanowire field effect transistors were implemented as highly sensitive chemical sensors for detection of NO2 and NH3 at room temperature. Due to a Debye screening length comparable to the nanowire diameter, the electric field applied over the back gate electrode was found to significantly affect the sensitivity as it modulates the carrier concentration. A strong negative field was utilized to refresh the sensors by an electrodesorption mechanism. In addition, different chemisorbed species could be distinguished from the “refresh” threshold voltage and the temporal response of the conductance. These results demonstrated a refreshable field effect sensor with a potential gas identification function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Fabrication and ethanol sensing characteristics of ZnO nanowire gas sensors
Wan, Q., Li, Q. H., Chen, Y. J., Wang, T. H., He, X. L., Li, J. P., & Lin, C. L. (2004) · Applied Physics Letters · doi:10.1063/1.1738932 · Cited by 2,005
Stable and highly sensitive gas sensors based on semiconducting oxide nanobelts
Comini, E., Faglia, G., Sberveglieri, G., Pan, Z., & Wang, Z. L. (2002) · Applied Physics Letters · doi:10.1063/1.1504867 · Cited by 1,459
Detection of CO and O2 Using Tin Oxide Nanowire Sensors
Kolmakov, A., Zhang, Y., Cheng, G., & Moskovits, M. (2003) · Advanced Materials · doi:10.1002/adma.200304889 · Cited by 1,049
Semiconductor Surfaces and Interfaces
Mönch, W. (1993) · Springer Series in Surface Sciences · doi:10.1007/978-3-662-02882-7 · Cited by 1,014
Nanoribbon Waveguides for Subwavelength Photonics Integration
Law, M., Sirbuly, D. J., Johnson, J. C., Goldberger, J., Saykally, R. J., & Yang, P. (2004) · Science · doi:10.1126/science.1100999 · Cited by 919
Detection of NO2 down to ppb Levels Using Individual and Multiple In2O3 Nanowire Devices
Zhang, D., Liu, Z., Li, C., Tang, T., Liu, X., Han, S., Lei, B., & Zhou, C. (2004) · Nano Letters · doi:10.1021/nl0489283 · Cited by 866
ZnO nanowire field-effect transistor and oxygen sensing property
Fan, Z., Wang, D., Chang, P.-C., Tseng, W.-Y., & Lu, J. G. (2004) · Applied Physics Letters · doi:10.1063/1.1836870 · Cited by 814
Self-citationDual-mode mechanical resonance of individual ZnO nanobelts
Bai, X. D., Gao, P. X., Wang, Z. L., & Wang, E. G. (2003) · Applied Physics Letters · doi:10.1063/1.1587878 · Cited by 495
In 2 O 3 nanowires as chemical sensors
Li, C., Zhang, D., Liu, X., Han, S., Tang, T., Han, J., & Zhou, C. (2003) · Applied Physics Letters · doi:10.1063/1.1559438 · Cited by 489
ZnO Nanowires Synthesized by Vapor Trapping CVD Method
Chang, P.-C., Fan, Z., Wang, D., Tseng, W.-Y., Chiou, W.-A., Hong, J., & Lu, J. G. (2004) · Chemistry of Materials · doi:10.1021/cm049182c · Cited by 379
Self-citationElectronic transport through individual ZnO nanowires
Li, Q. H., Wan, Q., Liang, Y. X., & Wang, T. H. (2004) · Applied Physics Letters · doi:10.1063/1.1759071 · Cited by 278
Zhang, Y., Kolmakov, A., Chrétien, S., Metiu, H. I., & Moskovits, M. (2004) · Nano Letters · doi:10.1021/nl034968f · Cited by 254
Electron theory of thin-film gas sensors
Geistlinger, H. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)85183-b · Cited by 158
Electrical properties of ZnO nanowire field effect transistors characterized with scanning probes
Fan, Z., & Lu, J. G. (2005) · Applied Physics Letters · doi:10.1063/1.1851621 · Cited by 142
Self-citationSurface Treatment and Doping Dependence of In2O3 Nanowires as Ammonia Sensors
Li, C., Zhang, D., Lei, B., Han, S. H., Liu, X., & Zhou, C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp0361531 · Cited by 121
Cited by
ZnO – nanostructures, defects, and devices
Schmidt-Mende, L., & MacManus-Driscoll, J. L. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70078-0 · Cited by 2,009
ZnO nanowire and nanobelt platform for nanotechnology
Wang, Z. L. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.02.001 · Cited by 1,157
Transfer Printing Techniques for Materials Assembly and Micro/Nanodevice Fabrication
Carlson, A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2012) · Advanced Materials · doi:10.1002/adma.201201386 · Cited by 917
25th Anniversary Article: Semiconductor Nanowires – Synthesis, Characterization, and Applications
Dasgupta, N. P., Sun, J., Liu, C., Brittman, S., Andrews, S. C., Lim, J., Gao, H., Yan, R., & Yang, P. (2014) · Advanced Materials · doi:10.1002/adma.201305929 · Cited by 880
ZnO Devices and Applications: A Review of Current Status and Future Prospects
Özgür, Ü., Hofstetter, D., & Morkoç, H. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2044550 · Cited by 839
Metadata
- Authors
- Fan, Z., & Lu, J. G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2005-03-17
- Volume
- 86
- Issue
- 12
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2071340400
- Cited by
- 435
- References
- 16
- FWCI
- 38.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.