Open-type magnetocardiograph with cylindrical magnetic shield
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We have developed an open-type magnetocardiograph (MCG) with a cylindrical magnetic shield—having an auxiliary magnetic shield—and 64 gradiometers based on low-transition temperature (Tc) superconducting quantum interference devices (SQUIDs). A revolving door is applied to the magnetic shield with the aim of providing easy access to a subject and easy operation. The cryostat attached to the MCG contains 64 low-Tc SQUIDs and is about 1m in height, so there must be an opening through the cylindrical surface of the magnetic shield. The properties of the magnetic shield were simulated using finite-element-method simulations and experiments. The results of the simulations indicated that the auxiliary magnetic shield recovers enough of the shielding performance of a magnetic shield with an opening that it performs like a magnetic shield without an opening. The shielding factor of the developed magnetic shield is above 46dB in the vicinity of the magnetic shield. Accordingly, the open-type MCG can clearly measure magnetocardiograms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tunnel junction dc SQUID: Fabrication, operation, and performance
Clarke, J., Goubau, W. M., & Ketchen, M. B. (1976) · Journal of Low Temperature Physics · doi:10.1007/bf00654826 · Cited by 261
Mager, A. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066714 · Cited by 167
Conventional magnetic shielding
Sumner, T. J., Pendlebury, J. M., & Smith, K. F. (1987) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/20/9/001 · Cited by 158
SQUID magnetocardiography: status and perspectives
Koch, H. (2001) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.919284 · Cited by 91
Tsukada, K., Miyashita, T., Kandori, A., Mitsui, T., Terada, Y., Sato, M., Shiono, J., Horigome, H., Yamada, S., & Yamaguchi, I. (2000) · International journal of cardiac imaging · doi:10.1023/a:1006376326755 · Cited by 70
Self-citationHosono, T., Chiba, Y., Shinto, M., Miyashita, S., Muramaki, K., Kandori, A., & Tsukada, K. (2000) · Fetal Diagnosis and Therapy · doi:10.1159/000053878 · Cited by 27
Self-citationYamada, S., Kuga, K., Yamaguchi, I., Tsukada, K., Miyashita, T., Noguchi, Y., Akamatsu, K., & Ebashi, T. (2000) · Journal of Arrhythmia · Cited by 17
Yokosawa, K., Kandori, A., Miyashita, T., Suzuki, D., Tsukada, K., & Tsukamoto, A. (2003) · Applied Physics Letters · doi:10.1063/1.1588737 · Cited by 14
Self-citationSuzuki, D., Tsukamoto, A., Yokosawa, K., Kandori, A., Ogata, K., & Tsukada, K. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.117 · Cited by 13
Self-citation
Research works printed but not linked: 1
- 2000, J. Arrhythmia, 16, 580
Cited by
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
Optically Pumped Magnetometers Recent Advances and Applications in Biomagnetism: A Review
Zhao, B., Li, L., Zhang, Y., Tang, J., Liu, Y., & Zhai, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3297109 · Cited by 80
Kinetic inductance magnetometer
Luomahaara, J., Vesterinen, V., Grönberg, L., & Hassel, J. (2014) · Nature Communications · doi:10.1038/ncomms5872 · Cited by 74
Gozzelino, L., Gerbaldo, R., Ghigo, G., Torsello, D., Bonino, V., Truccato, M., Grigoroscuta, M. A., Burdusel, M., Aldica, G., Sandu, V., et al. (2020) · Superconductor Science and Technology · doi:10.1088/1361-6668/ab7846 · Cited by 28
Metadata
- Authors
- Seki, Y., Kandori, A., Suzuki, D., & Ohnuma, M.
- Affiliations
- Hitachi (Japan) (JP)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2005-06-09
- Volume
- 86
- Issue
- 24
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1984725214
- Cited by
- 16
- References
- 9
- Citations by year
- 2023: 1 · 2020: 2 · 2017: 1 · 2016: 1 · 2014: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- magnetic shield, gradiometer, revolving door, cryostat, magnetocardiogram, finite element analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Open-type magnetocardiograph with cylindrical magnetic shield. https://app.cochat.ai/papers/10.1063/1.1946203
- The paper
- Seki, Y., Kandori, A., Suzuki, D., & Ohnuma, M. (2005). Open-type magnetocardiograph with cylindrical magnetic shield. Applied Physics Letters. https://doi.org/10.1063/1.1946203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.