The DOI matches its Crossref record.
Hard x-ray nanoprobe based on refractive x-ray lenses
Abstract
Based on nanofocusing refractive x-ray lenses a hard x-ray scanning microscope is currently being developed and is being implemented at beamline ID13 of the European Synchrotron Radiation Facility (Grenoble, France). It can be operated in transmission, fluorescence, and diffraction mode. Tomographic scanning allows one to determine the inner structure of a specimen. In this device, a monochromatic (E=21keV) hard x-ray nanobeam with a lateral extension of 47×55nm2 was generated. Further reduction of the beam size to below 20 nm is targeted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Breaking the 10 nm barrier in hard-X-ray focusing
Mimura, H., Handa, S., Kimura, T., Yumoto, H., Yamakawa, D., Yokoyama, H., Matsuyama, S., Inagaki, K., Yamamura, K., Sano, Y., et al. (2010) · Nature Physics · doi:10.1038/nphys1457 · Cited by 552
von der Kammer, F., Ferguson, P. L., Holden, P. A., Masion, A., Rogers, K. R., Klaine, S. J., Koelmans, A. A., Horne, N., & Unrine, J. M. (2012) · Environmental Toxicology and Chemistry · doi:10.1002/etc.723 · Cited by 448
Lombi, E., & Susini, J. (2009) · Plant and Soil · doi:10.1007/s11104-008-9876-x · Cited by 263
Metadata
- Authors
- Schroer, C. G., Kurapova, O., Patommel, J., Boye, P., Feldkamp, J., Lengeler, B., Burghammer, M., Riekel, C., Vincze, L., van der Hart, A., & Küchler, M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2005-09-13
- Volume
- 87
- Issue
- 12
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1997892290
- Cited by
- 371
- References
- 0
- FWCI
- 18.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hard x-ray nanoprobe based on refractive x-ray lenses. https://app.cochat.ai/papers/10.1063/1.2053350
- The paper
- Schroer, C. G., Kurapova, O., Patommel, J., Boye, P., Feldkamp, J., Lengeler, B., Burghammer, M., Riekel, C., Vincze, L., van der Hart, A., & Küchler, M. (2005). Hard x-ray nanoprobe based on refractive x-ray lenses. Applied Physics Letters. https://doi.org/10.1063/1.2053350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.