The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Direct velocity measurements of the flow past drag-reducing ultrahydrophobic surfaces
Abstract
A series of experiments are presented which study the flow kinematics of water past drag-reducing superhydrophobic surfaces. The ultrahydrophobic surfaces are fabricated from silicon wafers using photolithography and are designed to incorporate precise patterns of micrometer-sized ridges aligned in the flow direction. The ridges are made hydrophobic through a chemical reaction with an organosilane. An experimental flow cell is used to measure the velocity profile and the pressure drop as a function of the flow rate for a series of rectangular cross-section microchannel geometries and ultrahydrophobic surface designs. The velocity profile across the microchannel is determined through microparticle image velocimetry (μ-PIV) measurements capable of resolving the flow down to lengthscales well below the size of the surface features. Through these detailed velocity measurements, it is demonstrated that slip along the shear-free air-water interface supported between the hydrophobic micrometer-sized ridges is the primary mechanism responsible for the drag reduction observed for flows over ultrahydrophobic surfaces. A maximum slip velocity of more than 60% of the average velocity in the microchannel is found at the center of the shear-free air-water interface whereas the no-slip boundary condition is found to hold along the surface of the hydrophobic ridges. The experimental velocity and pressure drop measurements are compared to the predictions of numerical simulations and an analytical theory based on a simple model of an ultrahydrophobic surface composed of alternating shear-free and no-slip bands with good agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Cited by
Superhydrophobic surfaces: from structural control to functional application
Zhang, X., Shi, F., Niu, J., Jiang, Y., & Wang, Z. (2008) · J. Mater. Chem. · doi:10.1039/b711226b · Cited by 1,768
Bazant, M. Z., Kilic, M. S., Storey, B. D., & Ajdari, A. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.10.001 · Cited by 916
Recent advances in the potential applications of bioinspired superhydrophobic materials
Darmanin, T., & Guittard, F. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta02071e · Cited by 555
Metadata
- Authors
- Ou, J., & Rothstein, J. P.
- Venue
- Physics of Fluids
- Publisher
- AIP Publishing
- Published
- 2005-10-01
- Volume
- 17
- Issue
- 10
- ISSN
- 1070-6631 (ISSN-L)
- 1089-7666
- OpenAlex
- W2072538485
- Cited by
- 530
- References
- 1
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct velocity measurements of the flow past drag-reducing ultrahydrophobic surfaces. https://app.cochat.ai/papers/10.1063/1.2109867
- The paper
- Ou, J., & Rothstein, J. P. (2005). Direct velocity measurements of the flow past drag-reducing ultrahydrophobic surfaces. Physics of Fluids. https://doi.org/10.1063/1.2109867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.