Hollow cathode theory and experiment. I. Plasma characterization using fast miniature scanning probes
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
A detailed study of the spatial variation of plasma density, temperature, and potential in hollow cathodes using miniature fast scanning probes has been undertaken in order to better understand the cathode operation and to provide benchmark data for the modeling of the cathode performance and life described in a companion paper. Profiles are obtained throughout the discharge and in the very high-density orifice region by pneumatically driven Langmuir probes, which are inserted directly into the hollow cathode orifice from either the upstream insert region inside the hollow cathode or from the downstream anode-plasma region. A fast transverse-scanning probe is also used to provide radial profiles of the cathode plume as a function of position from the cathode exit. The probes are extremely small to avoid perturbing the plasma; the ceramic tube insulator is 0.05cm in diameter with a probe tip area of 0.002cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage wave form to the probe as it is scanned through the plasma at speeds of up to 2m∕s to produce the profiles with a spatial resolution of about 0.05cm. At discharge currents of 10–25A from the 1.5-cm-diameter hollow cathode, the plasma density inside the cathode is found to exceed 1014cm−3, with the peak density occurring upstream of the orifice. The plasma potentials on axis inside the cathode are found to be in the 10–20V range with electron temperatures of 2–5eV, depending on the discharge current and gas flow rate. A potential discontinuity or double layer of less than 10V is observed in the orifice region, and under certain conditions appears in the bright “plasma ball” in front of the cathode. This structure tends to change location and magnitude with discharge current, gas flow, and orifice size. A potential maximum proposed in the literature to exist in or near the cathode orifice is not observed. Instead, the plasma potential increases from the orifice exit both radially and axially over several centimeters to values of 5–10V above the anode voltage. The potential and temperature profiles inside the cathode are insensitive to anode configuration changes that alter the discharge voltage at a given flow. Application of an axial magnetic-field characteristic of the cathode region found in ring-cusp ion thrusters increases the plasma density in the cathode plume, but does not significantly change the potential or temperature. Measurements of the plasma profiles and the internal cathode parameters for a hollow cathode operating at discharge currents of up to 25A in xenon are shown and discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Characteristics of Electrical Discharges in Magnetic Fields
(1950) · Journal of the American Medical Association · doi:10.1001/jama.1950.02920020129032 · Cited by 1,128
The characteristics of electrical discharges in magnetic fields
Charp, S. (1950) · Journal of the Franklin Institute · doi:10.1016/0016-0032(50)90527-8 · Cited by 708
The characteristics of electrical discharges in magnetic fields
Guthrie, A., & Wakerling, R. K. (1949) · McGraw-Hill eBooks · Cited by 303
Langmuir probe measurements in an inductively coupled plasma source
Schwabedissen, A., Benck, E. C., & Roberts, J. R. (1997) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.55.3450 · Cited by 149
Highly Ionized Hollow Cathode Discharge
Lidsky, L. M., Rothleder, S. D., Rose, D. J., Yoshikawa, S., Michelson, C., & Mackin, R. J. (1962) · Journal of Applied Physics · doi:10.1063/1.1729002 · Cited by 132
High current hollow cathode phenomena
Friedly, V. J., & Wilbur, P. J. (1992) · Journal of Propulsion and Power · doi:10.2514/3.23526 · Cited by 80
A Mercury plasma-bridge neutralizer.
RAWLIN, V. K., & PAWLIK, E. V. (1968) · Journal of Spacecraft and Rockets · doi:10.2514/3.29363 · Cited by 75
Steinbrüchel, C. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119774 · Cited by 71
Laser-induced fluorescence characterization of ions emitted from hollow cathodes
Williams, G. J., Smith, T. B., Domonkos, M., Gallimore, A. D., & Drake, R. P. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.901252 · Cited by 67
Theory of cylindrical and spherical Langmuir probes in the limit of vanishing Debye number
Parrot, M., Storey, L. R. O., Parker, L. W., & Laframboise, J. G. (1982) · The Physics of Fluids · doi:10.1063/1.863725 · Cited by 66
Measurements of Ions from High-Current Hollow Cathodes Using Electrostatic Energy Analyzer
Kameyama, I., & Wilbur, P. J. (2000) · Journal of Propulsion and Power · doi:10.2514/2.5601 · Cited by 49
Research works printed but not linked: 3
- 1962, J. Appl. Phys., 22, 2490
- Huddlestone, 1966, Plasma Diagnostics Techniques, 113
- 1998, 21st International Symposium on Space Technology and Science
Cited by
Tutorial: Physics and modeling of Hall thrusters
Boeuf, J.-P. (2017) · Journal of Applied Physics · doi:10.1063/1.4972269 · Cited by 504
The use of hollow cathodes in deposition processes: A critical review
Muhl, S., & Pérez, A. (2015) · Thin Solid Films · doi:10.1016/j.tsf.2015.02.066 · Cited by 166
Potential fluctuations and energetic ion production in hollow cathode discharges
Goebel, D. M., Jameson, K. K., Katz, I., & Mikellides, I. G. (2007) · Physics of Plasmas · doi:10.1063/1.2784460 · Cited by 151
Self-citationRecent progress in research and development of hollow cathodes for electric propulsion
Lev, D. R., Mikellides, I. G., Pedrini, D., Goebel, D. M., Jorns, B., & McDonald, M. (2019) · Reviews of Modern Plasma Physics · doi:10.1007/s41614-019-0026-0 · Cited by 125
Self-citationWear Mechanisms in Electron Sources for Ion Propulsion, II: Discharge Hollow Cathode
Mikellides, I. G., Katz, I., Goebel, D. M., Jameson, K. K., & Polk, J. E. (2008) · Journal of Propulsion and Power · doi:10.2514/1.33462 · Cited by 104
Self-citation
Metadata
- Authors
- Goebel, D. M., Jameson, K. K., Watkins, R. M., Katz, I., & Mikellides, I. G.
- Affiliations
- California Institute of Technology (US)
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2005-12-01
- Volume
- 98
- Issue
- 11
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1974310028
- Cited by
- 129
- References
- 11
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 11 · 2023: 6 · 2022: 10 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 5 · 2017: 8 · 2016: 8 · 2015: 4 · 2014: 10 · 2013: 3 · 2012: 9
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physics (publishedVersion)
- Funders
- National Aeronautics and Space Administration
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Gyrotron and Vacuum Electronics Research
- Keywords
- hollow cathode, plasma density profile, plasma temperature, plasma electric potential, electric double layer, Langmuir probes, fast scanning probe, miniature probe, electron temperature, axial magnetic field, current-voltage characteristics, cathode life, discharge current, gas flow rate, plasma ball, anode configuration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.