CoChat

Hollow Cathode and Keeper-Region Plasma Measurements Using Ultra-Fast Miniature Scanning Probes

Goebel, Dan, Katz, I., Watkins, Ron, Jameson, Kristina · 2004 · 40th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.

Overview

Integrity signals

Registry

Crossref · 10.2514/6.2004-3430

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 10 references

Research works printed but not linked: 3

  1. Mikellides I., AIAA Paper #2004-3817, 40th JointPropulsionConference,Ft.Lauderdale,FL,July11-14,2004.
  2. Chen F., 1966, Plasma Diagnostics Techniques
  3. Kameyama I., ISTSPaper#98-a-2-17, 21stIntl.SymposiumonSpaceTechnologyandScience,SonicCity,Omiya,Japan,May24-21,1998.

Cited by

See all 72

Metadata

Authors
Goebel, D., Katz, I., Watkins, R., & Jameson, K.
Affiliations
Jet Propulsion Laboratory (US)
Venue
40th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit
Published
2004-06-26
OpenAlex
W2074404964
Cited by
63
References
10
Citations by year
2025: 1 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 2 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 1
FWCI
16.52
Type
conference paper
Language
en
Open access
closed
Locations
AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit (publishedVersion)
Funders
  • National Aeronautics and Space Administration
  • Jet Propulsion Laboratory
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Magnetic confinement fusion research
Keywords
hollow cathode, ion thrusters, Langmuir probes, plasma density, plasma temperature, plasma electric potential, xenon discharge, cathode pressure, deep space propulsion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hollow Cathode and Keeper-Region Plasma Measurements Using Ultra-Fast Miniature Scanning Probes. https://app.cochat.ai/papers/10.2514/6.2004-3430
The paper
Goebel, D., Katz, I., Watkins, R., & Jameson, K. (2004). Hollow Cathode and Keeper-Region Plasma Measurements Using Ultra-Fast Miniature Scanning Probes. 40th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit. https://doi.org/10.2514/6.2004-3430

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.