The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Noninvasive determination of optical lever sensitivity in atomic force microscopy
Abstract
Atomic force microscopes typically require knowledge of the cantilever spring constant and optical lever sensitivity in order to accurately determine the force from the cantilever deflection. In this study, we investigate a technique to calibrate the optical lever sensitivity of rectangular cantilevers that does not require contact to be made with a surface. This noncontact approach utilizes the method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] to calibrate the spring constant of the cantilever in combination with the equipartition theorem [J. L. Hutter and J. Bechhoefer, Rev. Sci. Instrum. 64, 1868 (1993)] to determine the optical lever sensitivity. A comparison is presented between sensitivity values obtained from conventional static mode force curves and those derived using this noncontact approach for a range of different cantilevers in air and liquid. These measurements indicate that the method offers a quick, alternative approach for the calibration of the optical lever sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Cited by
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Self-citationHigh-frequency microrheology reveals cytoskeleton dynamics in living cells
Rigato, A., Miyagi, A., Scheuring, S., & Rico, F. (2017) · Nature Physics · doi:10.1038/nphys4104 · Cited by 281
Schillers, H., Rianna, C., Schäpe, J., Luque, T., Doschke, H., Wälte, M., Uriarte, J. J., Campillo, N., Michanetzis, G. P. A., Bobrowska, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05383-0 · Cited by 268
The applications of atomic force microscopy to vision science
Last, J. A., Russell, P., Nealey, P. F., & Murphy, C. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5470 · Cited by 100
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Higgins, M. J., Proksch, R., Sader, J. E., Polcik, M., Mc Endoo, S., Cleveland, J. P., & Jarvis, S. P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-01-01
- Volume
- 77
- Issue
- 1
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2006688507
- Cited by
- 239
- References
- 1
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.