CoChat

Aircraft instrument for simultaneous, in situ measurement of NO3 and N2O5 via pulsed cavity ring-down spectroscopy

Dubé, William P., Brown, Steven S., Osthoff, Hans D., Nunley, Maya R., Ciciora, Steven J., Paris, Mark W., McLaughlin, Richard J., Ravishankara, A. R. · 2006 · Review of Scientific Instruments
Cited by 148

The DOI matches its Crossref record.

Abstract

This article describes a cavity ring-down spectrometer (CaRDS) specifically designed and constructed for installation on the NOAA WP-3D Orion (P-3) aircraft for sensitive, rapid in situ measurement of NO3 and N2O5. While similar to our previously described CaRDS instrument, this instrument has significant improvements in the signal-to-noise ratio, the time resolution, and in overall size and weight. Additionally, the instrument utilizes a custom-built, automated filter changer that was designed and constructed to meet the requirement for removal of particulate matter in the airflow while allowing fully autonomous instrument operation. The CaRDS instrument has a laboratory detection sensitivity of 4×10−11cm−1 in absorbance or 0.1pptv (pptv denotes parts per trillion volume) of NO3 in a 1s average, although the typical detection sensitivities encountered in the field were 0.5pptv for NO3 and 1pptv for N2O5. The instrument accuracy is 25% for NO3 and 20%–40% for N2O5, limited mainly by the uncertainty in the inlet transmission. The instrument has been deployed on the P-3 aircraft as part of a major field campaign in the summer of 2004 and during several ground and tower deployments near Boulder, CO.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2176058

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dubé, W. P., Brown, S. S., Osthoff, H. D., Nunley, M. R., Ciciora, S. J., Paris, M. W., McLaughlin, R. J., & Ravishankara, A. R.
Venue
Review of Scientific Instruments
Published
2006-03-01
Volume
77
Issue
3
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1571074872
Cited by
148
References
0
FWCI
3.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.