The DOI matches its Crossref record.
Mechanism of NO2 detection in carbon nanotube field effect transistor chemical sensors
Abstract
We report an experimental method that clearly determines the sensing mechanism of carbon-nanotube field effect transistors. The nanotube/electrode contacts are covered with a thick and long passivation layer that hinders their exposure to chemicals in a controlled fashion, leaving only the midsection of the nanotube exposed. In the case of nitrogen dioxide, a considerably delayed response is fully consistent with the diffusion of the gas through the passivation layer. The results clearly indicate that nitrogen dioxide detection is due to changes at the interfaces between the nanotube and the electrodes and not to molecules adsorbed on the nanotube surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Liu, H., Liu, Y., & Zhu, D. (2011) · J. Mater. Chem. · doi:10.1039/c0jm02922j · Cited by 1,629
Li, H., Yin, Z., He, Q., Li, H., Huang, X., Lu, G., Fam, D. W. H., Tok, A. I. Y., Zhang, Q., & Zhang, H. (2012) · Small · doi:10.1002/smll.201101016 · Cited by 1,536
Practical Chemical Sensors from Chemically Derived Graphene
Fowler, J. D., Allen, M. J., Tung, V. C., Yang, Y., Kaner, R. B., & Weiller, B. H. (2009) · ACS Nano · doi:10.1021/nn800593m · Cited by 1,447
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Potential Applications of Carbon Nanotubes
Endo, M., Strano, M. S., & Ajayan, P. M. (2007) · Topics in Applied Physics · doi:10.1007/978-3-540-72865-8_2 · Cited by 481
Carbon nanotubes: Sensor properties. A review
Zaporotskova, I. V., Boroznina, N. P., Parkhomenko, Y. N., & Kozhitov, L. V. (2016) · Modern Electronic Materials · doi:10.1016/j.moem.2017.02.002 · Cited by 464
A sensitivity-enhanced field-effect chiral sensor
Torsi, L., Farinola, G. M., Marinelli, F., Tanese, M. C., Omar, O. H., Valli, L., Babudri, F., Palmisano, F., Zambonin, P. G., & Naso, F. (2008) · Nature Materials · doi:10.1038/nmat2167 · Cited by 440
Dai, J., Ogbeide, O., Macadam, N., Sun, Q., Yu, W., Li, Y., Su, B.-L., Hasan, T., Huang, X., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00459a · Cited by 378
Graphene Field‐Effect Transistor and Its Application for Electronic Sensing
Zhan, B., Li, C., Yang, J., Jenkins, G., Huang, W., & Dong, X. (2014) · Small · doi:10.1002/smll.201400463 · Cited by 312
Carbon nanotubes based transistors as gas sensors: State of the art and critical review
Bondavalli, P., Legagneux, P., & Pribat, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.025 · Cited by 284
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Metadata
- Authors
- Zhang, J., Boyd, A., Tselev, A., Paranjape, M., & Barbara, P.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2006-03-20
- Volume
- 88
- Issue
- 12
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2036717939
- Cited by
- 180
- References
- 0
- FWCI
- 20.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.