The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High resolution frequency standard dissemination via optical fiber metropolitan network
Abstract
We present in this article results on a new dissemination system of an ultrastable reference signal at 100MHz on a standard fiber network. The 100MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solutions are suggested in order to improve the frequency stability and to further extend the distribution distance. Nevertheless, our system is a good tool for the best cold atom fountains comparison between laboratories, up to 100km, with a relative frequency resolution of 10−14 at 1s integration time and 10−17 for 1day of measurement. The distribution system may be upgraded to fulfill the stringent distribution requirements for the future optical clocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationOptical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
High-stability transfer of an optical frequency over long fiber-optic links
Williams, P. A., Swann, W. C., & Newbury, N. R. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001284 · Cited by 385
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Stability of the Proton-to-Electron Mass Ratio
Shelkovnikov, A., Butcher, R. J., Chardonnet, C., & Amy-Klein, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.150801 · Cited by 219
Self-citation
Metadata
- Authors
- Narbonneau, F., Lours, M., Bize, S., Clairon, A., Santarelli, G., Lopez, O., Daussy, C., Amy-Klein, A., & Chardonnet, C.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-06-01
- Volume
- 77
- Issue
- 6
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1992177849
- Cited by
- 166
- References
- 2
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.