The DOI matches its Crossref record; 137 of the 137 references it cites were found in a registry or an index.
Remote transfer of ultrastable frequency references via fiber networks
Abstract
Three distinct techniques exist for distributing an ultrastable frequency reference over optical fibers. For the distribution of a microwave frequency reference, an amplitude-modulated continuous wave (cw) laser can be used. Over kilometer-scale lengths this approach provides an instability at 1 s of ∼3×10−14 without stabilization of the fiber-induced noise and ∼1×10−14 with active noise cancellation. An optical frequency reference can be transferred by directly transmitting a stabilized cw laser over fiber and then disseminated to other optical and microwave regions using an optical frequency comb. This provides an instability at 1 s of 2×10−14 without active noise cancellation and 3×10−15 with active noise cancellation [Recent results reduce the instability at 1 s to 6×10−18.] Finally, microwave and optical frequency references can be simultaneously transmitted using an optical frequency comb, and we expect the optical transfer to be similar in performance to the cw optical frequency transfer. The instability at 1 s for transfer of a microwave frequency reference with the comb is ∼3×10−14 without active noise cancellation and <7×10−15 with active stabilization. The comb can also distribute a microwave frequency reference with root-mean-square timing jitter below 16 fs integrated over the Nyquist bandwidth of the pulse train (∼50 MHz) when high-bandwidth active noise cancellation is employed, which is important for remote synchronization applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Self-citationRanka, J. K., Windeler, R. S., & Stentz, A. J. (2000) · Optics Letters · doi:10.1364/ol.25.000025 · Cited by 2,179
Hedgehog is an early and late mediator of pancreatic cancer tumorigenesis
Thayer, S. P., di Magliano, M. P., Heiser, P. W., Nielsen, C. M., Roberts, D. J., Lauwers, G. Y., Qi, Y. P., Gysin, S., Castillo, C. F.-D., Yajnik, V., et al. (2003) · Nature · doi:10.1038/nature02009 · Cited by 1,480
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Self-citationColloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Self-citationTakamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Ultrashort Laser Pulse Phenomena
(2006) · Elsevier eBooks · doi:10.1016/b978-0-12-215493-5.x5000-9 · Cited by 847
Research works printed but not linked: 11
- 2000, Can. J. Phys., 78, 639, 10.1139/cjp-78-7-639 · doi:10.1139/cjp-78-7-639
- 2004, 2004 IEEE International Topical Meeting on Microwave Photonics Technical Digest, 201
- Sullivan, 1990, Characterization of Clocks and Oscillators: NIST Technical Note 1337
- 2003, Proceedings of the 2003 IEEE International Frequency Control Symposium and PDA Exhibition Jointly with the 17th European Frequency and Time Forum, 516
- 2004, IEEE Proceedings
- 2001, IEEE Int. Frequency Control Symposium, 156
- 2006, International Workshop on Advances In Precision Tests and Experimental Gravitation in Space, 14
- Blatt, 1999, Proceedings of ICOLS’99, 80
- M. Calhoun, R. Sydnor, and W. Diener, The Interplanetary Network Progress Report, 15 February 2002, pp. 48–142.
- 2002, Proceedings of the 2002 IEEE International Frequency Control Symposium and PDA Exhibition, 510
- Hänsch, 1994, Frontiers in Laser Spectroscopy, Proceedings of the International School of Physics, 359
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationQuantum repeaters based on atomic ensembles and linear optics
Sangouard, N., Simon, C., de Riedmatten, H., & Gisin, N. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.33 · Cited by 1,888
“…is currently an active area of research aiming at the transmission of frequency references over large distances in optical fibers, in order to synchronize or compare remote opticalfrequency atomic clocks (Coddington et al., 2007; Foreman et al., 2007b; Musha et al., 2008; Newbury et al., 2007).”
BackgroundUltralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Longer-Baseline Telescopes Using Quantum Repeaters
Gottesman, D., Jennewein, T., & Croke, S. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.070503 · Cited by 442
“[10] Supplemental material [11] Seth M.”
BackgroundUltrastable laser interferometry for earthquake detection with terrestrial and submarine cables
Marra, G., Clivati, C., Luckett, R., Tampellini, A., Kronjäger, J., Wright, L., Mura, A., Levi, F., Robinson, S., Xuereb, A., et al. (2018) · Science · doi:10.1126/science.aat4458 · Cited by 407
“atomic clock comparisons and suppressed using active cancellation techniques (21).”
Method
Metadata
- Authors
- Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2007-02-01
- Volume
- 78
- Issue
- 2
- Pages
- 021101-021101
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2074669670
- Cited by
- 403
- References
- 137
- Citations by year
- 2026: 7 · 2025: 19 · 2024: 19 · 2023: 16 · 2022: 19 · 2021: 24 · 2020: 18 · 2019: 20 · 2018: 19 · 2017: 24 · 2016: 20 · 2015: 23 · 2014: 22 · 2013: 18 · 2012: 21
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Photonic Communication Systems
- Keywords
- frequency transfer, optical fiber communication, optical frequency combs, optical frequency standard, frequency instability, active noise control, timing jitter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Remote transfer of ultrastable frequency references via fiber networks. https://app.cochat.ai/papers/10.1063/1.2437069
- The paper
- Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007). Remote transfer of ultrastable frequency references via fiber networks. Review of Scientific Instruments. https://doi.org/10.1063/1.2437069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.