Anomalous attenuation of the positive temperature coefficient of resistivity in a carbon-black-filled polymer composite with electrically conductive in situ microfibrils
The DOI matches its Crossref record.
Abstract
The positive temperature coefficient of resistivity (PTCR) of in situ microfibrillar carbon black∕poly (ethylene terephthalate)∕polyethylene composite attenuates dramatically after a sufficient time of isothermal treatment without oxygen above the melting region of polyethylene. The inhomogeneous surface microstructure and the large size of the microfibrils are the key factors controlling PTCR attenuation, through which a model is proposed to explain this anomalous phenomenon. An effective approach is accordingly developed to prepare recyclable semicrystalline thermoplastic based electrically conductive polymer composite with steady conductivity in wide temperature range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
“Competing organic devices suffer in terms of repeatability, commonly exhibiting less than 100 stable thermal cycles (16, 19, 20).”
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Su, Y., Ma, C., Chen, J., Wu, H., Luo, W., Peng, Y., Luo, Z., Li, L., Tan, Y., Omisore, O. M., et al. (2020) · Nanoscale Research Letters · doi:10.1186/s11671-020-03428-4 · Cited by 287
Metadata
- Authors
- Xu, X.-B., Li, Z.-M., Dai, K., & Yang, M.-B.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2006-07-17
- Volume
- 89
- Issue
- 3
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2022264189
- Cited by
- 42
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.