The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Open accessAbstract
Significance: We have successfully fabricated very unique ultraflexible temperature sensors that exhibit changes in resistivity by six orders of magnitude or more for a change in temperature of only 5 °C or less. Our approach offers an ideal solution to measure temperature over a large area with high spatial resolution, high sensitivity of 0.1 °C or less, and fast response time of 100 ms. Indeed, such a large change of resistivity for our sensors can significantly simplify the readout circuitry, which was the key to demonstrate, to our knowledge, the world’s first successful measurement of dynamic change of temperature in the lung during very fast artificial respiration. Furthermore, we have demonstrated real-time multipoint thermal sensing using organic transistor active-matrix circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“For measuring spatial temperature gradients, an organic active matrix with polymer PTC sensor pads was fabricated on a PI substrate, which exhibits a bending insensitivity and high spatial resolution (Figure 7A and 7B).[103]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [103]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Self-citationSchwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · cited 1×
“There have been reports of the potential application of flexible electrodes on ultrathin substrates (4), flexible sensors that measure biological signals, electrocardiograms, temperature, pressure (5, 6), organic amplifier systems (7), high-sensitivity pressure sensors (8), and ultrathin and imperceptible devices (9,…”
Ultralow-power organic complementary circuits
Klauk, H., Zschieschang, U., Pflaum, J., & Halik, M. (2007) · Nature · doi:10.1038/nature05533 · Cited by 1,398
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389
Self-citationUltrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,012
Cited by
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Self-citationSkin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Metadata
- Authors
- Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., Voit, W., Sekitani, T., & Someya, T.
- Affiliations
- Japan Science and Technology Agency (JP)
- The University of Tokyo (JP)
- The University of Texas at Dallas (US)
- University of Tokyo Hospital (JP)
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2015-11-09
- Volume
- 112
- Issue
- 47
- Pages
- 14533-14538
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC4664374
- OpenAlex
- W2171005488
- Cited by
- 382
- References
- 39
- Citations by year
- 2026: 14 · 2025: 25 · 2024: 34 · 2023: 34 · 2022: 39 · 2021: 42 · 2020: 53 · 2019: 39 · 2018: 51 · 2017: 35 · 2016: 16
- FWCI
- 16.89
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (30723481)
- National Science Foundation (2013155309)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Keywords
- flexible temperature sensors, semicrystalline polymers, multi-point temperature measurement, spatial temperature gradient, in vivo temperature measurement, rat lung, body temperature
- MeSH terms
- Animals, Body Temperature, Graphite, Polymers, X-Ray Diffraction, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultraflexible, large-area, physiological temperature sensors for multipoint measurements. https://app.cochat.ai/papers/10.1073/pnas.1515650112
- The paper
- Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., Voit, W., Sekitani, T., & Someya, T. (2015). Ultraflexible, large-area, physiological temperature sensors for multipoint measurements. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1515650112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.