The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Open accessAbstract
We report herein a glucose biosensor based on glucose oxidase (GOx) immobilized on ZnO nanorod array grown by hydrothermal decomposition. In a phosphate buffer solution with a pH value of 7.4, negatively charged GOx was immobilized on positively charged ZnO nanorods through electrostatic interaction. At an applied potential of +0.8V versus Ag∕AgCl reference electrode, ZnO nanorods based biosensor presented a high and reproducible sensitivity of 23.1μAcm−2mM−1 with a response time of less than 5s. The biosensor shows a linear range from 0.01to3.45mM and an experiment limit of detection of 0.01mM. An apparent Michaelis-Menten constant of 2.9mM shows a high affinity between glucose and GOx immobilized on ZnO nanorods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-Temperature Ultraviolet Nanowire Nanolasers
Huang, M. H., Mao, S., Feick, H., Yan, H., Wu, Y., Kind, H., Weber, E., Russo, R., & Yang, P. (2001) · Science · doi:10.1126/science.1060367 · Cited by 8,923
A colorimetric sensor array for odour visualization
Rakow, N. A., & Suslick, K. S. (2000) · Nature · doi:10.1038/35021028 · Cited by 1,490
Electrochemical Biosensing Platforms Using Platinum Nanoparticles and Carbon Nanotubes
Hrapovic, S., Liu, Y., Male, K. B., & Luong, J. H. T. (2004) · Analytical Chemistry · doi:10.1021/ac035143t · Cited by 1,064
Jia, J., Wang, B., Wu, A., Cheng, G., Li, Z., & Dong, S. (2002) · Analytical Chemistry · doi:10.1021/ac011116w · Cited by 653
Zinc oxide nanocomb biosensor for glucose detection
Wang, J. X., Sun, X. W., Wei, A., Lei, Y., Cai, X. P., Li, C. M., & Dong, Z. L. (2006) · Applied Physics Letters · doi:10.1063/1.2210078 · Cited by 595
Self-citationOptical properties of epitaxially grown zinc oxide films on sapphire by pulsed laser deposition
Sun, X. W., & Kwok, H. S. (1999) · Journal of Applied Physics · doi:10.1063/1.370744 · Cited by 541
Self-citationOhara, T. J., Rajagopalan, R., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00087a008 · Cited by 379
Immobilization of uricase on ZnO nanorods for a reagentless uric acid biosensor
Zhang, F., Wang, X., Ai, S., Sun, Z., Wan, Q., Zhu, Z., Xian, Y., Jin, L., & Yamamoto, K. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.05.070 · Cited by 348
Burmeister, J. J., & Gerhardt, G. A. (2001) · Analytical Chemistry · doi:10.1021/ac0010429 · Cited by 289
Yu, J., Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00199-4 · Cited by 171
Yang, Y., Yang, H., Yang, M., liu, Y., Shen, G., & Yu, R. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.07.071 · Cited by 162
Palmisano, F., Rizzi, R., Centonze, D., & Zambonin, P. G. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00107-x · Cited by 140
Separation-free electrochemical immunosensor for rapid determination of atrazine
Keay, R. W., & McNeil, C. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00008-6 · Cited by 131
Room-Temperature Ultraviolet Lasing from Zinc Oxide Microtubes
Sun, X. W., Yu, S. F., Xu, C., Yuen, C., Chen, B. J., & Li, S. (2003) · Japanese Journal of Applied Physics · doi:10.1143/jjap.42.l1229 · Cited by 94
Self-citationHigh resistive layers toward ZnO-based enzyme modified field effect transistor
Ogata, K., Koike, K., Tanite, T., KOMURO, T., Sasa, S., Inoue, M., & Yano, M. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.12.022 · Cited by 21
Cited by
ZnO – nanostructures, defects, and devices
Schmidt-Mende, L., & MacManus-Driscoll, J. L. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70078-0 · Cited by 2,009
Interaction of Nanoparticles with Edible Plants and Their Possible Implications in the Food Chain
Rico, C. M., Majumdar, S., Duarte-Gardea, M., Peralta-Videa, J. R., & Gardea-Torresdey, J. L. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf104517j · Cited by 1,468
One-dimensional ZnO nanostructures: Solution growth and functional properties
Xu, S., & Wang, Z. L. (2011) · Nano Research · doi:10.1007/s12274-011-0160-7 · Cited by 1,361
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Metadata
- Authors
- Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2006-09-18
- Volume
- 89
- Issue
- 12
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2079704578
- Cited by
- 442
- References
- 15
- FWCI
- 30.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.